OPERATION
10
Typhoon EV 1592/1512 (03--03)
TROUBLE SHOOTING
PROBLEM CAUSE SOLUTION
Machine does not run.
ON/OFF switch is OFF. Turn switch to ON.
Vacuum not plugged to wall outlet. Plug power cord to wall outlet.
Faulty ON/OFF switch. Contact Service Center.
Faulty Power Cord Contact Service Center.
Faulty wiring. Contact Service Center.
Building circuit breaker tripped. Reset circuit breaker.
Vacuum motor overheated. Find obstruction. Cool motor for 20
minutes.
Faulty vacuum motor. Contact Service Center.
Machine has little or no suction.
Hose is clogged Clear hose.
Holes in hose. Replace hose.
Intake is clogged. Remove hose and clear obstruction.
Drain hose knob is loose or open. T ighten drain knob.
Lid is not securely latched. Latch both latches down securely.
Worn gasket which is leaking air. Inspect all gaskets, replace if
necessary.
Recovery tank or bag is full. Empty tank or bag.
Squeegee has poor pick up.
Debris is wedged under squeegee
blade.
Wipe off squeegee blade.
Squeegee blades are worn. Replace squeegee blades.
Vacuum hose on squeegee mount is
loose.
Push vacuum hose on securely.
Recovery tank is full. Empty tank.
SPECIFICATIONS
MODEL NUMBERS Typhoon EV 1592 Typhoon EV 1512
LENGTH 29 in / 740 mm 29 in / 740 mm
WIDTH 15.5 in / 390 mm 15.5 in / 390 mm
WEIGHT 44 lb / 20kg 44 lb / 20kg
VACUUM MOTOR
8.5 amps, 1.3 hp, 120V, 980 watt s 10.7 amps, 1.7 hp, 120V, 1242 watt s
POWERCORDLENGTH 50ft/15m 50ft/15m
SQUEEGEE PATH WIDTH
(OPTIONAL)
27 in / 690 mm,
34 in / 840 mm,
40 in / 990 mm
27 in / 690 mm,
34 in / 840 mm,
40 in / 990 mm
WA TER LIFT 92 in / 2340 mm 120 in / 3050 mm
TANK CAPACITY 15 gal / 57 L 15 gal / 57 L
VACUUM BAG CAPACITY .3 bu .3 bu
DECIBEL RATING AT
OPERATOR’ S EAR
80.5 dBA 80.5 dBA