4. To complete the installation procedure, click Finish .
Figure 24 Finish flash update
Next actions
FPS-8 and FPS-10 flash prommers must be updated using
Phoenix
.
Updating FPS-8 and FPS-10 flash prommer software
Steps
1. Start
Phoenix
service software, and log in.
2. Choose the correct connection for your flash prommer: File→Manage Connections...
3. Choose Flashing→Prommer maintenance .
4. To update the FPS-8/FPS-10 software, click Update, and select the appropriate file
fps8upd.ini
(for FPS-8)
or
fpsxupd.ini
(for FPS-10) from
C:\Program Files\Nokia\Phoenix\Flash
.
Figure 25 Flash directory window
RM-123; RM-145