EasyManua.ls Logo

Nokia 6310 - Standby mode

Nokia 6310
29 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONFIDENTIAL
18 (29)
NPE-4 6310/NPL-1 6310i Repair Hints
Customer Care Europe, Middle East & Africa Version 3.0 Approved
SCCE Training Group Date 22.04.2003
© NMP 2003
Checked by:
SCCE Training Group
Approved by:
SCCE
Check TXC at C761, power level 19 and 5 (See picture below).
Oscilloscope settings:
Ampl: 500mV
Time/Div: 10ms/Div
AC/DC/GND: AC
Power level 19
Power level 5
If the TXC signals are not ok, check UEM D200.
Check TXP signal at J760 (See picture below).
Oscilloscope settings:
Ampl: 500mV
Time/Div: 1ms/Div
AC/DC/GND: AC
If the TXP signal is not ok, check UPP D400.
Check System Clk = 26 MHz at C752 (see picture at chapter Electrical faults/ Totally dead)
If also the System Clk is ok, check the following voltages:
Check VR3 = 2.8 VDC at C602 (supply voltage for 26 MHz oscillator G740)
Check VR4 = 2.8 VDC at C601
Check VR5 = 2.8 VDC at C604
Check VR6 (VBB) = 2.8 VDC at C605
Check VR1A (VCP) = 4.7 VDC at C600 (control voltage VC for SHF oscillator)
Check VR7 = 2.8 VDC at C299 (supply voltage VCC for SHF oscillator)
Check VREF01 and VREF02 = 1.35 VDC at R726
If one of the voltages described above is not ok, check UEM D200.
If all voltages are ok, change Hagar N600.