  NPE-4 6310/NPL-1 6310i  Repair Hints 
Customer Care Europe, Middle East & Africa    Version 3.0 Approved 
SCCE Training Group  Date 22.04.2003   
 
© NMP 2003 
 Checked by: 
SCCE Training Group 
Approved by: 
SCCE 
Flowchart - No service → no TX 
 
Set Phone to TX -Mode 
EGSM 897.4 MHz,
Ch. 37, power level 10. 
Set Spectrum Analyzer to
 TX EGSM 897.4 MHz, Ch.37.
Check TX 
EGSM 897,4 MHz 
at R656.
Check TX 
PCN 1747.8 MHz 
at L602.
Check TX I/Q 
67.71 kHz signal at 
C764 and C766 at 
both sides.
Check UEM D200.
Check 
TXP VDC > 1.8 V 
at C760 with 
oscilloscope. 
Check TXC
 signal at C761 
with oscilloscope. 
Check UPP 
D400.
Check UEM D200.
Check 26 MHz 
at C752.
Check the
 following voltages:
 VR2 = 2.8 VDC at C294; VR3 = 2.8 VDC at 
C602; VR4 = 2.8 VDC at C601; 
VR5 = 2.8 VDC at C604; VR6 = 2.8 VDC at 
C605; VR7 = 2.8 VDC at C299; 
VrefRF01 & VrefRF02 = 1.35 VDC at R726;
VR1A = 4.7 V at R600. 
Hagar N600 
defective.
Check UEM D200.
Check 26 MHz 
circuit, especially 
G740.
 
No Service/
No TX EGSM/PCN.
Set Phone to TX -Mode 
PCN 1747.8 MHz, 
Ch.700, power level 10. 
Set Spectrum Analyzer to 
PCN 1747.8 MHz, CH. 700.
Check TX EGSM/PCN path from 
Hagar to X802 antenna connector 
for shorts or disconnections. 
Probably N840 defective.
OK
nOK
nOK
OK
nOK
OK
nOK
OK
nOK
OK
nOK
OK
nOK
OK