E-240W-A unit data sheet
36
7368 ISAM ONT E-240W-A Product Guide
3FE-46974-AAAA-TCZZA Issue: 01
4.2.1 TR-069 support
The ONT supports the reading of optical parameters via TR-069:
• laser bias current
• voltage
• temperature
• received signal levels
• lower thresholds
These are the same optical parameters supported in the GUI. For more information,
see Table 16 in the chapter “Configure an E-240W-A indoor ONT”.
The ONT supports the status retrieval and configuration of the following Wi-Fi
parameters via TR-069:
• channel
• SSID
• password for WPA and WEP
• Tx power (transmission rate in percentage of maximum transmit power)
These are the same TR-069 object parameters that are supported in the GUI. For
more information, see Tables 12, 22, and 23 in the chapter “Configure an E-240W-A
indoor ONT”.
The ONT also supports TR-069 statistics for LAN, WAN, and WiFi.
4.2.2 TR-104 parameter extension support for voice
service
A proprietary attribute has been added to the TR-104 Voice Service object structure
to enable the ACS to configure the name of the embedded GSIP XML file to be
selected.
The TR-104 Voice Service Object is:
InternetGatewayDevice.Services.VoiceService.{i}.Capabilities.SIP.
The proprietary attribute is: X_ALU-COM_XML_File_Name_Path.
4.2.3 TR-111 support
The E-240W-A ONT supports TR-111, which extends the WAN Management
Protocol defined in TR-069 to enhance the ability to remotely manage LAN devices.
The device-gateway association enables an ACS to identify the associated gateway
through which a device is connected.
Release 06.00.00h | January 2019 | Edition 08