Procedure 
3FE-49441-ABAA-TCZZA
 
Issue 1 
 
 
 
10 
 
DANGER 
 
 
Hazard 
 
Fiber cables transmit invisible laser light. To avoid eye damage or blindness, never look directly 
into fibers, connectors, or adapters. 
 
WARNING 
 
 
Equipment Damage 
 
Be careful to maintain a bend radius of no less than 1.5 in. (3.8 cm) when connecting the fiber 
optic cable. Too small of a bend radius in the cable can result in damage to the optic fiber. 
Connect the fiber optic cable with SC/APC adapter into the SC/APC connector on the bottom of 
the ONT. 
 
 Note: Fiber cable preparation varies depending on the type and size of the inside or 
outside plant fiber cable being spliced to the SC/APC fiber optic pigtail cable. 
 
11 
Connect the power cable to the power connector. 
 
12 
Power up the unit by using the power switch. 
 
13 
If used, enable the Wi-Fi service by pressing the WLAN button; see  Figure 7-1, “G-2426G-B 
indoor ONT connections” (p. 89) for the location of the WLAN button. 
 
14 
If used, configure the SLID; see the Nokia ONT Configuration, Management, and 
Troubleshooting Guide for more information. 
 
 Note: A new SLID or the old SLID may be used with the replacement ONT. 
If a new SLID is used, the new SLID must also be programmed at the P-OLT using TL1 or 
a network manager. 
If the old SLID is used, no changes need to be made at the P-OLT; see the operations and 
maintenance documentation for the OLT for more details. 
 
15 
Verify the ONT LEDs, voltage status, and optical signal levels; see the Nokia ONT Hardware 
and Cabling Installation Guide.