Abnormal Condition
Mode Selector set to GAS; AC indicated. Refrigerator operating on GAS.
Remedy: Replace Eyebrow board.
Abnormal Condition
Mode Selector set to AUTO; LP indicated. Refrigerator operating on AC
Remedy: Replace Eyebrow board
Abnormal Condition
Mode Selector set to GAS; No operation indicated. Refrigerator operating on GAS.
Remedy: Replace Eyebrow board.
Abnormal Condition
Mode Selector set to DC ON; No operation indicated. Refrigerator operating on DC.
Remedy: Replace Eyebrow board.
Abnormal Condition
Mode Selector set to AUTO; LP indicated. 120 volts AC supplied to refrigerator.
Remedy: Check the 5 amp fuse. If OK, replace Power Supply.
Figure 11.72 Auto Operation
Figure 11.73 Auto Operation
Figure 11.74 Gas Operation
Figure 11.75 DC Operation
Figure 11.76 Auto Operation
1