8 Additional information
BU 0200 en-3118 265
Example of frequency inverter addressing
Frequency inverter Addressing via DIP switch S1 Resulting Node ID Node ID AG
DIP2 DIP1 Frequency inverters
FI 1 ON ON 32 33
FI 2
OFF
ON
34
35
FI 3
OFF
ON
36
37
FI 4
OFF
OFF
38
39
Pos: 73 5 /Anlei tung en/El ektr onik/FU und Star ter/8 . Zus atzinfor mati one n/Syst embus _ Ergänz ung _Infor mati on - CANo pen A G [ SK 2 xxE] @ 5\mod_1397120446073_388.docx @ 126200 @ @ 1
Information
CANopen absolute encoders
In applications with CANopen absolute encoders, the encoders must be assigned to the relevant FI via the node
ID. If there is one encoder and four frequency inverters in the system bus, for example, and the encoder is to
work together with FI3, the encoder must be set to a node ID of 37, see table above Node ID AG