EasyManua.ls Logo

Nordson 2302 - Page 43

Nordson 2302
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation 4-5
2. Preparation of equipment
(continuef$
3SP!Z(24BAR)
x
18lN.MAx
w CM)
III
TOP VIEW OF
H200 MODULE
22. (Automatic guns only) Set the input air pressure to the gun solenoid
valve(s) to 35 psi (2.4 bar). Further adjustment of gun air pressure
may be necessary, depending on the viscosity of the material and
gun response requirements.
23. (Manual guns only) Adjust the discharge force of material from the
nozzle by adjusting the input air pressure to the applicator pump.
24. Multiple Series H200 modules or guns maybe adjusted as follows:
a. Briefly trigger the guns at the desired line speed.
b. Note the position of each bead (see example at left).
- To delay material flow (make the bead slightly shorter), loosen the
\r.
locking-nut and turn the loading screw clockwise (see illustration
at left).
d.
To advance material flow (make the bead slightly longer), loosen
the locking nut and turn the loading screw counterclockwise (see
illustration at left).
e.
Repeat the procedure as necessary to coordinate the modules.
f. After adjusting a loading screw, tighten the locking nut.
NOTE: The adjustable loading screw is intended for minor adjustments
in bead position. If bead positioning varies greatly from one gun to
another, check to see that the time intervals on the timer are set to
deposit the beads in the same position.
25. The system is ready for use.
8 No&on Corporation 1994
AU Rights Reserved
P/N 106 ?OlA
41-23OOSP - Issued 1194

Related product manuals