Disassembly and Repair 743
Actuator assembly cleaning or
replacement
Ygure 7.33
- Removing the Actuator
Assembly Can.
t Yigure 7.34 - Valve Cap and Screws.
If the actuator air valve is stuck and does not move, it may be damaged
or need cleaning. Work on a clean work surface. The actuator
assembly contains magnets which will pick up small particles that may
damage the assembly or affect its performance.
1. Complete steps 1 through 7 of the Actuator assembly replacement
procedure earlier in this Section.
.
2. Remove the screws from the can. Pull the can straight out from the
valve body.
3. Remove the valve cap screws with a 4-mm hex key.
4. Remove the magnet assembly.
Figure 7.35 - Removing the Magnet
Assembly.