Pump Packing and Solvent Chamber Fluid Guide
3
Part 108044G
E 2003 Nordson Corporation
Type Q Concentrate Mixing Instructions
WARNING: Do not take internally. For industrial use only. Avoid direct
contact. Eye and skin irritant. Refer to the MSDS shipped with the solvent
chamber fluid for more information.
Mix one gallon of distilled water with 2.6 fluid ounces of Type Q concentrate
as follows:
1. Fill a 1-gallon-(3.8-liter) round container
3
/
4
full of distilled water at
70−100 _F.
2. Use a rotating agitator to mix the water until it forms a whirlpool at the
container’s center.
3. Slowly pour one full bottle (2.6 oz.) of Type Q concentrate into the
whirlpool.
4. Add the remaining distilled water to make one gallon, and mix for an
additional 15 minutes.
NOTE: The mixture may separate after prolonged shelf time. If it does, mix
again before using.