EasyManua.ls Logo

Nordson 25B - Section 5 Maintenance

Nordson 25B
103 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-5
Operation and Maintenance
© 2024 Nordson Corporation
1044131-06
Routine Startup
See Figure 4-2
Preparation
Check the levels of the:
• coating material supply (5)

• air lubricator (4)
Make sure that the
• siphon rod and strainer (6) are submerged in coating material, or pressure-feed
system is operating


• compressed air is available to run the pump
• drain rod (12) is in a waste container (13) (circulating systems only)
• pump, coating material supply, and waste container are grounded
Startup
1. Use the following formula to calculate the air pressure required to produce the desired
output pressure:
output pressure --- pump ratio = air pressure required
WARNING: Maximum air pressure for all versions of the 25B pump is 7 bar (100 psi).
Do not exceed this pressure.
Calculate the required air pressure for desired output pressure as shown in the following
examples:
2:1 pump: 100 psi desired --- 2 = 50 psi air pressure
4:1 pump: 200 psi desired --- 4 = 50 psi air pressure
16:1 pump: 1200 psi desired --- 16 = 75 psi air pressure required.
27:1 pump: 2000 psi desired --- 27 = 74 psi air pressure required.
NOTE: 
pressure at the spray device will vary, depending on many factors, including material


gauge at the spray device inlet or as close to the inlet as practical.
2. 󰀨
regulator (3) to the air pressure that will produce the desired output pressure.
3. Purge air from the system:
• Dead-end system: Trigger the spray devices and watch for spitting as air is purged.
Stop when the spray pattern is continuous and even.
• Circulating system: Close the circulation valve (10) and open the drain valve (11).


minute running at the desired number of cycles per minute. Trigger the spray device(s)
to purge air from them.