Instruction Sheet
Part 108152−01
E 2017 Nordson Corporation
108152−01
Air Lubricator Adjustments and Oils
Adjustments
Air lubricators are shipped with Nordson pumps or are optional equipment. Refer
to your pump manual for lubricator installation instructions.
Lubricators are not pre-adjusted at the factory. To properly adjust the lubricator,
follow the instructions below:
1. Fill the lubricator bowl with Nordson Vitalizer oil.
NOTE: Use only Nordson Vitalizer oil or an oil recommended by your Nordson
representative. Disregard any oil recommendations in the OEM instruction
sheet shipped with the air lubricator.
2. Start the pump and run it at the desired operating speed.
3. Adjust the lubricator to deliver oil at the rate given for your pump in the
following table.
Pump Model Strokes per drop of oil
180D 10−15
360D 10−15
25B 17−25
64B 15−20
32/64 17−25
CP 15−20
JP 5−10
Ordering Nordson Vitalizer Oil
To order parts, call the Nordson Finishing Customer Support Center at
(800) 433−9319 or your local Nordson representative.
Quantity Part Number
1 Pint (0.47 liters) 900214
1 Quart (0.95 liters) 900215
1 Gallon (3.79 liters) 900216
5 Gallons (18.93 liters) 900217