21
Part 7580607_01
E 2018 Nordson Corporation
Periodic Maintenance
Note: You may need to perform these procedures more or less often,
depending on your application requirements.
Component Maintenance Procedure
Compressed Air System
Openthedropleganduseaclean,whiteclothtocheckforcontaminants.
Correct any problems immediately. Drain the air filters and change the
elements as necessary.
Electrical System
Tighten all electrical connections and inspect tor loose or broken wires. Check
the electrical system t or electrical safety every 12 months. The system must
comply with all local, state, and federal codes.
System Grounds
Check all equipment grounds. Electrical equipment must be grounded
according to the relevant code. For maximum transfer efficiency and safety,
electrostatic equipment must be grounded to provide a complete circuit from
the product, through the hangers, conveyors booth and back to the gun
controllers.
Refer to Grounding in the Safety section of this manual and to publication
number TCTT- 06- 3881 on the Nordson emanuals website
(http://emanuals.nordson.com/finishing) for more information on powder
coating system grounding.
Air Tubing Pressurise the system and identify if there any air leaks. Replace or repair any
damaged fittings or tubing.
Sieve Maintenance
Refer to the AZO Rotary Sieve manual for more information on sieve
maintenance. Available upon request from Nordson.
Festo Valve Island Maintenance
Manual: Valve terminals MPA- S (Typ32)
https://www.festo.com/cat/de_de/data/doc_engb/PDF/EN/TYP32_EN.PDF