1
Nordson Corporation
Encore
r
LT Manual Powder Spray Systems
OPERATOR CARD P/N 1604859-01
WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions
in this document and all other related documentation.
Controller Interface
Trigger LED
Smart Flow LED
Flow Air Output (Classic)
Flow Air % Output (Smart Flow)
Atomizing Air Output (Classic)
Total Flow Output (Smart Flow)
Select Charge Mode Settings
KV/μA Setting/Output
STD/AFC
Mode Toggle
Enable/Disable
Pressing the Enable/Disable button for three
seconds puts the controller to sleep (low power
mode). The displays and LEDs turn off. To wake the
controller press the button again.
The system goes to sleep automatically if no activity
is detected for approximately 15 minutes. Pulling the
gun trigger, pressing the purge switch, or pressing a
button on the controller interface wakes the controller.
When the gun is triggered the Trigger LED
is lit, and actual kV/μA outputs are displayed. When
not triggered the kV/μA setpoint is displayed. The two
air flow displays always show the setpoints.
The Smart Flow LED lights when the
controller is configured for Smart Flow mode. Refer to
Powder Flow Setting for an explanation.
Controller Configuration
During power up or wake up from disable, press and
hold the + and − buttons on the kV/uA panel for 1
second. When the kV/
μA panel displays F − 1 for
function 1 the controller is in configuration mode.
To change functions, press the Plus or Minus buttons
on the kV/
μA panel. To change function values press
the Plus or Minus buttons on the Flow Air panel. To
save your settings and exit Configuration Mode,
press the Enable/Disable button.
Function No. Name Settings Default
1 Gun Type 0 = Encore 0
2 Fluidizing 0 = Hopper, 1 = Box, 3 = Disable 0
3 Electrostatic Control 0 = Custom, 1 = Classic, 2 = PE 0
4 Powder Flow Control 0 = Smart, 1 = Classic 0
5 Cable Length 0 = 6 meters, 1 = 12 meters, 2 = 18 meters 0
6 Vibratory Box Delay on, 0−90 seconds 30