Custom Electrostatic Mode
Custom Mode is the factory default mode. In Custom
mode, both kV and A can be adjusted
independently. Both the STD and AFC LEDs are lit
when this mode is configured.
Use the View button
to toggle the display
between kV and uA.
S The valid STD (kV) range is 0 or 25100 kV.
S The valid AFC (A) range is 5100 A.
Classic Electrostatic Mode
Classic Mode is the optional electrostatic mode. In
Classic mode you can choose to control kV (STD)
output or A (AFC) output, but not both at the same
time. When using the AFC mode, you set a top limit
for current output. If the current output goes above
the limit, kV output is decreased to maintain the
current setting.
The controller must be configured to use this mode.
Refer to your system manual for configuration
settings.
Press the STD/AFC button
to toggle between
STD and AFC mode.
Press the View button
to toggle the display
between kV and A.
Valid ranges are the same as in Custom Mode.
Powder Flow Settings
Smart Flow Mode This is the factory default mode.
In this mode, you set the Total Flow rate and the Flow
Air %. If you decrease the flow air %, the flow air
pressure decreases, but the atomizing air pressure
increases, so that the result is that the powder
velocity remains the same.
Classic Flow Mode This is the traditional method
of setting powder flow and velocity, by setting flow
and atomizing air percentages separately and
balancing them manually for optimum results.
Press the + and buttons to select the desired
setpoint. The longer a button is pressed the faster the
units change.
Smart Flow Mode
The Smart Flow LED lights when the
controller is configured for Smart Flow mode.
sets the powder flow rate (Flow Air %).
sets the powder velocity (Total Flow).
Setting values for both are 099%.
Set Total Flow first to obtain the desired pattern size
and penetration, then set Flow Air % for the desired
powder flow.
NOTE: If either Total Flow or Flow Air are set to 0%
then the controller cannot output any air when
triggered and no powder is pumped.
Classic Flow Mode
To use Classic Flow mode, the controller must be
configured for it. Refer to your system manual for
configuration settings.
sets the flow air pressure as a percentage
of maximum pressure.
sets the atomizing air pressure as a
percentage of maximum pressure.
Setting values for both are 099% of maximum air
pressure.