WARNING: Allow only qualied personnel to perform the following tasks. Follow the
safety instructions in this document and all other related documentation.
Battery Replacement
WARNING: When the backup battery is installed in a Class I, Division 2 Groups A B C D
or Class I Zone 2 II C hazardous location, adhere to the following:
• Explosion Hazard – Do not connect or disconnect the battery unless the area is known
to be free of ignitable concentrations.
• When removing and installing the new battery, exteme care must be used not to short
the metal chassis parts across the battery terminals.
• Remove watches, rings, and other metal objects.
• Use tools with insultated handles.
• Do not lay tools or other metal objects on top of the battery.
• If the battery replacement kit is damaged in anyway or shows signs of leakage, contact
the manufaturer immediately.
• Do not dispose of battery in a re.
• Dispose of old battery according to local codes.
• Electrical safety precautions must be followed when installing or servicing this
equipment. To prevent risk of electrical shock, turn o and lockout all power sources
to the unit before making electrical connections or servicing.
CAUTION: Only use the recommended manufacturer battery for replacement. Refer to
the Parts section for replacement battery information.
1. Shut down power to the system.
2. See Figure 5 for backup battery location inside pedestal enclosure. Remove the
backup battery unit from the din rail and move to a clean at surface area.
3. Remove screws securing the the battery cover or enclosure to expose battery.
4. Disconnect the terminal of the battery.
5. Take note of the battery orientation and remove the battery.
CAUTION: Be sure to install the battery in the correct orientation.
6. Install the new battery and make terminal connections.
7. Secure the cover or enclosure with screws and install backup battery unit back onto
din rail.