EasyManuals Logo

Nordyne JT5BD Series User Manual

Nordyne JT5BD Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
OUTDOOR TEMPERATURE
(° F)
0 102030405060
Suc.
Press
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
13 111 113 23 132 120 32 152 127 41 173 134 51 181 149 61 201 172 70 221 195
14 118 111 24 138 118 33 157 125 42 176 132 52 188 146 62 208 167 71 228 188
15
125 109
25
144 116
34
162 123
43
180 130
53
195 143
63
215 163
72
235 182
16 132 107 26 149 114 35 167 121 44 184 128 54 202 140 64 222 158 73 242 176
17
139 105
27
155 112
36
171 119
45
187 126
55
209 138
65
229 154
74
249 170
18 146 103 28 161 110 37 176 117 46 191 124 56 216 135 66 236 149 75 256 164
19 153 101 29 167 108 38 181 115 47 195 122 57 223 132 67 243 145 76 263 158
OUTDOOR TEMPERATURE
(° F)
0 102030405060
Suc.
Press
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
Suc.
Press.
Liquid
Press.
Disch.
Temp.
12 120 107 21 135 119 29 150 131 37 165 142 46 169 158 56 184 177 66 200 196
13 127 105 22 141 117 30 155 129 38 169 140 47 176 155 57 191 172 67 207 189
14
134 103
23
147 115
31
160 127
39
173 138
48
183 152
58
198 168
68
214 183
15 141 101 24 153 113 32 165 125 40 176 136 49 190 149 59 205 163 69 221 177
16
148 99
25
159 111
33
169 123
41
180 134
50
197 146
60
212 159
70
228 171
17 155 97 26 165 109 34 174 121 42 184 132 51 204 144 61 219 154 71 235 165
18 162 95 27 171 107 35 179 119 43 187 130 52 211 141 62 226 150 72 242 159
Table 11. Charging Table for JT5BD-018K Series Heat Pump (1.5 Ton Units)
Table 12. Charging Table for JT5BD-024KA Series Heat Pump (2 Ton Units)
REFRIGERANT CHARGING TABLES - HEATING MODE
Shaded boxes indicate fl ooded conditions.
Rated design values. Suction pressure will vary from design value if outdoor air fl ow, entering dry bulb, or entering wet bulb temperatures vary.
1. All pressures are listed psig and all temperatures in °F
2. Discharge temperatures greater than charted values indicate an undercharged system.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordyne JT5BD Series and is the answer not in the manual?

Nordyne JT5BD Series Specifications

General IconGeneral
BrandNordyne
ModelJT5BD Series
CategoryHeat Pump
LanguageEnglish

Related product manuals