13 SEER =Refrigerant Charging Tables for Cooling Mode of Operation
Continued
4
TON 70 75 80 85 90 95 100 105
Suct. Dis. Dis. Dis. Dis. Dis. Dis, Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis. Dis.
Press. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp. Press. Temp.
67 157 131
69 159 136 174 139
71 161 142 176 144 191 147
73 162 150 178 149 193 151 209 154
75 166 152 180 155 196 156 211 159 226 161
77 183 158 197 161 213 163 228 166 iiiiiiiiii_i!iiii,iiiiiil_69iiii_ii
79 201 165 215 168 230 170 245 173 iiiili_oiXiXii.iiiilii_ii:751iiiii
81 219 171 233 174 247 177 iHiiii262;:iii_!i.iHiiiii_iX791ili!ii!iiiii!i!i_7i!!iiii,iiiii!i!_((_!iiill
83 222 175 236 178 251 181 264 183 iiiiili_'_91iii:!ii.iiiiilii_8_ii!ii!i!i}i
85 240 182 254 185 268 188 iiiitii_ii[iiiiiii,iiiitli;i_i_ii,!,ili
87 257 189 272 192 286 195
89 275 196 289 199
91 293 204
93
Refriqerant Charging Chart Legend for Coolinq Mode of Operation
* Note: All pressures are listed in psig. and all temperatures in °F.
- Shaded Boxes indicate flooded conditions
_,_,_ - Rated Design Values. Suction Pressure will be lower than design
value if indoor air flow, entering dry bulb, or entering wet bulb
temperatures are lower than design.
- Discharge temperatures greater than charted values indicate an
undercharged system.
13