27
Specifications
•Specifications may be changed without prior notice.
The capacity may differ slightly, depending on the water
pressure, water supply, piping conditions, and water temperature.
Specification
NR98-DVC-CA
Indoor Wall Mounted
Power Vented
Direct Ignition
15-150 psi
2 L/min. (0.5 GPM)
600mm (23.6") x 350mm (13.8") x 270mm (10.2")
55 lbs.
0.95L (0.2 Gallon)
3/4"
3/4"
3/4"
120 VAC (60Hz)
NG : 108W LP : 96W Freeze Prevention 161W
Zincified Steel Plate/Polyester Coating
Stainless Steel
Copper Sheeting, Copper Tubing
Flame Rod, Thermal Fuse, Lightning Protection
Device (ZNR), Electric Leakage Prevention Device
(GFCI), Overheat Prevention Device, Freezing
Prevention Device, Fan Rotation Detector
Anchoring Screws
Specifications
Performance
Item
Model Name
Type
Ignition
Operating Pressure
Minimum Flow Rate
Dimensions (Height) x (Width) x (Depth)
Weight
Water Holding Capacity
Accessories
Installation
Air Supply/Exhaust
Connection Sizes
Power Supply
Materials
Water Inlet
Hot Water Outlet
Gas Inlet
Supply
Consumption
Casing
Flue Collar
Heat Exchanger
Safety Devices
Item
Gas
Consumption
Maximum Hot Water Capacity
Capacity Range
Temperature Settings
Default Temperature Options
NG
LP
25°C (45°F) Rise
Maximum Performance
199,900 btuh
199,900 btuh
Minimum Performance
11,000 btuh
11,000 btuh
28.2 L/min. (7.5 Gal./min.)
2-37 L/min. (0.5-9.8 Gal./min.)
37-48°C (99-118°F) (In 1°C (5°F) intervals),
50-80°C (122-176°F) (In 5°C (10°F) intervals),
83°C (181°F) (20 Options)
50, 55, 60, 83°C (122,131,140,181°F)
(Original is 50°C (122°F))