30 Installing the chassis
Check
Accessory Use to
6 lock washers Connect all leads
2 washers Connect the ground
stud
Before you begin the installation, verify that you have the following tools
and materials:
Cable
Crimping tool for crimping the lugs onto the cable
Heat gun to shrink the tubing around the cable (optional)
7/16-inch hex wrench
Phillips screwdriver
Note: Nortel does not supply the cables for connecting the DC
power supply to the DC input power source. Select cables that
comply with the electrical code of the country where you are using
the DC power supply.
To prepare cables for connecting the power supply:
Step Action
1
Strip 0.81 in. (2.1 cm) of insulation from the ends of the cables.
2
Crimp the lugs onto the cables using a standard crimping tool.
Failure to properly crimp the lugs onto the cables constitutes a
safety hazard.
3
If necessary, use a heat gun to shrink the tubing around the cable.
—End—
To install a DC power supply:
Step Action
1
Make sure that the power switch is turned off.
2
Remove the filler panel or cover from the power bay, if necessary.
To remove the filler panel, see "Removing a module or power filler
panel" (page 14).
3
Grasp the handle of the new power supply
Nortel Ethernet Routing Switch 8600
Quick Start
NN46205-310 01.01 Standard
4.1 21 December 2006