Powering up the system 35
turn off the power supplies for a short period of time and then
turn on the power supplies again simultaneously.
—End—
Installing a breaker interface panel
If you are installing a breaker interface panel (BIP), see Installing the
Breaker Interface Panel for the 8010co Chassis.
Installing a PCMCIA software card
Insert the PCMCIA card into the PCMCIA slot of the CPU.
Powering up the system
Upon power up, all modules run a set of internal self-diagnostics.
Turning AC power supplies on
To turn on an Ethernet Routing Switch 8000 Series chassis with an AC
power supply:
Step Action
1 Verify that the AC power cords are connected to AC power outlets.
2
Turn the power switch on each AC power supply to the on position.
Do not operate the 8010co chassis with only one power supply.
Note: If your chassis contains two or three power supplies, turn
on the power supplies simultaneously. If you wait longer to turn
on the second power supply, one of the power supplies can shut
off within 7 seconds. To correct this condition, turn off the power
supplies for a short period of time and then turn on the power
supplies again simultaneously.
3
Verify that the power LED on each power supply lights green.
4
Verify that the power supply status LEDs and the fan LED on the
8691SF or 8692SF CPU modules light green.
5
Verify that air is flowing from the cooling fans out through the vents
of the chassis.
Note: The fan tray red fail LED may light briefly while the fans
are powering to operational speed.
—End—
Nortel Ethernet Routing Switch 8600
Quick Start
NN46205-310 01.01 Standard
4.1 21 December 2006
Copyright © 2006 , Nortel Networks Nortel Networks Confidential
.