EasyManuals Logo

Nortel BayStack 425-24T User Manual

Nortel BayStack 425-24T
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
215658-B
8
This guide includes information about the following topics:
“Before you begin” (next)
“Package contents for the BayStack 425 switch” on page 9
“Installing the switch on a table or shelf” on page 10
“Installing the switch in an equipment rack” on page 11
“Connection requirements” on page 12
“Connecting AC power” on page 14
“Checking LEDs” on page 18
“Initial switch setup” on page 20
“Related publications” on page 24
Before you begin
Make sure the area where you will install and use the BayStack 425 meets these
environmental requirements:
Ambient temperature between 32° and 104° F (0° and 40° C)
Relative humidity between 10% and 85% noncondensing
No nearby heat sources such as hot air vents or direct sunlight
No nearby sources of severe electromagnetic noise
No excessive dust
Adequate power source within six feet; one 15-Amp circuit required for each
unit.
At least 2 inches (5.08 cm) on each side of the switch unit for ventilation.
Adequate space at the front and rear of the switch for access to cables.
If you are installing a single BayStack 425 on a table or shelf, make sure the
surface will support at least 10 to 15 pounds (4.5 to 6.8 kilograms).
book.book Page 8 Thursday, July 29, 2004 10:07 PM

Other manuals for Nortel BayStack 425-24T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nortel BayStack 425-24T and is the answer not in the manual?

Nortel BayStack 425-24T Specifications

General IconGeneral
BrandNortel
ModelBayStack 425-24T
CategoryNetwork Router
LanguageEnglish

Related product manuals