Nortel BayStack 425-24T - Installation Procedures; Before You Begin

Nortel BayStack 425-24T
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
215658-B
8
This guide includes information about the following topics:
“Before you begin” (next)
“Package contents for the BayStack 425 switch” on page 9
“Installing the switch on a table or shelf” on page 10
“Installing the switch in an equipment rack” on page 11
“Connection requirements” on page 12
“Connecting AC power” on page 14
“Checking LEDs” on page 18
“Initial switch setup” on page 20
“Related publications” on page 24
Before you begin
Make sure the area where you will install and use the BayStack 425 meets these
environmental requirements:
Ambient temperature between 32° and 104° F (0° and 40° C)
Relative humidity between 10% and 85% noncondensing
No nearby heat sources such as hot air vents or direct sunlight
No nearby sources of severe electromagnetic noise
No excessive dust
Adequate power source within six feet; one 15-Amp circuit required for each
unit.
At least 2 inches (5.08 cm) on each side of the switch unit for ventilation.
Adequate space at the front and rear of the switch for access to cables.
If you are installing a single BayStack 425 on a table or shelf, make sure the
surface will support at least 10 to 15 pounds (4.5 to 6.8 kilograms).