6 CONTROLLING THE EXTRACTION
TOWER
6.1 Extractor hood control panel
Extraction control
Switch on/lift extraction tower position
1 2 3
6 7
4
5
Decrease extraction speed
1 2 3
6 7
4
5
Increase extraction speed
1 2 3
6 7
4
5
Switch o/lower extraction tower position
1 2 3
6 7
4
5
Extraction speed indication
1 2 3
6 7
4
5
Cleaning indication for grease lter
1 2 3
6 7
4
5
Cleaning indication for recirculation lter (optional)
1 2 3
6 7
4
5
6.2 User modes
This device can be used in the exhaust or recirculation mode
(standard setting upon delivery)
6.2.1 Exhaust mode
The air sucked in is rst cleaned by the grease lters before
being removed to the outside. This can be achieved by making
use of a series of channels connected between the device and
a wall exhaust cover.
To set the device in exhaust mode, press and hold the key
combination
+
and
and for 3 seconds when the
extraction tower is closed.
The led next to the Cleaning indication for recirculation lter will
blink 3x.
6.2.2 Recirculation mode
The air sucked in is rst cleaned by the grease lters. The scents
are then removed in the recirculation lter before re-entering the
kitchen.
To set the device in recirculation mode (default setting), press
and hold the key combination
+
and
and for 3 seconds
when the extraction tower is closed.
The led next to the Cleaning indication for recirculation lter will
be on for 3 seconds.
6.3 Switch on and off and run-out function

WARNING: When the extraction is activated, the
extraction tower automatically rises to the desired
height at the rear of the induction hob. Therefore,
ensure nothing can hinder its movement.
Extraction tower
Switch on
Display
Press
and hold for 2 seconds
LED
lights up
Switch on run-out function
1st LED
blinks
Press
Switch off
LED
o
Press
Run-out function: This function starts at the end of cooking.
For a xed time, the remaining cooking vapours will be extracted
from the kitchen by the extraction tower at low extraction mode
and at a height of 7 cm. When recirculation is selected, the
lters are also dried.
The run-out time is set to 30 minutes by default in the recirculation
mode and 10 minutes in exhaust mode. It is recommended that
this function be allowed to carry out its function completely. At
the end of the run-out time, the motor and the extraction tower
will automatically switch o and the tower will close.