48
OPERATION 7. HOW TO USE BASIC FUNCTION
Parameter List
No. Name Description Setting range Initial
value
00
Initial display
Displays 00 at first when selecting the
parameter setting (PRM) mode.
02
VS-5FX output
specifications
This function must be designated at first
when using VS-5FX(-1) after delivery.
Designates
the combination of program
and switch output numbers.
0: 16-program, 40-switch
1: 32-program, 24-switch
0
01
ABSOCODER
rotation direction
Designates the rotation direction of
ABSOCODERs shaft in which the current
position value increase.
0: Increases the current position value by
rotating CW direction.
1: Increases the current position value by
rotating CCW direction.
0: CW direction
Display:
1: CCW direction
Display:
0
99
Origin point
setting
Designates the machines origin point
(000) to VARICAM.
0
98
Current position
setting
Designates the machine's current position
value to VARICAM by the key input.
Setting unit is 0.5
°
.
0 to 359.5
°
0
7-5-1. Selects the Parameter Setting (PRM) Mode
Keeps pressing [MODE] key more than 1 second.
POSITION and MODE display areas are blinking, and
changes to mode selection screen.
Repeatedly presses [MODE] key, and selects the
parameter setting (PRM) mode.
Presses [SET] key.
Changes to the parameter setting (PRM) mode.
Operation (RUN) mode Switch setting (SET)mode Parametr setting (PRM) mode
PRM LED
is ON
LED ON/OFF state
: ON
: OFF
: BLINK
POINT
The password would be already set if "
" is
displayed. Refer to APPENDIX 1.