iii
2. Storage
CAUTION
- Do not store VARICAM in a place exposed to water, or toxic gas and liquid.
- Be sure to store VARICAM in designed temperature and humidity range, and do not exposed to direct
sunlight.
- Be sure to consult with NSD when VARICAM is stored for long periods.
3. Transport
CAUTION
- Do not hold the cable or shaft of ABSOCODER during transport; otherwise, it will cause injury or malfunction.
4. Installation
CAUTION
- Do not step on the ABSOCODER sensor or place heavy objects on the controller; otherwise, it will cause
injury or malfunction.
- Do not block the exhaust port or allow any foreign matter to enter VARICAM; otherwise, it will cause fire or
VARICAM failure.
- Be sure to secure VARICAM and ABSOCODER with the provided brackets; otherwise, it may cause
malfunction, injury, or drop.
- Be sure to secure the specified distance between VARICAM and the control panel or other equipment;
otherwise, it may cause malfunction.
5. Wiring
DANGER
- Be sure to secure the terminal block firmly; otherwise, it will cause fire.
- Be sure to mount the terminal cover provided with VARICAM, before supplying the power, starting operation
after the installation, and wiring; otherwise, it may cause electric shock.
CAUTION
- Be sure to keep the sensor cable, control cable, and communication cable at least 300 mm away from the
main circuit and power line; otherwise it may cause injury or malfunction.
- Be sure to connect all cables correctly; otherwise, it may cause injury or malfunction.
- Be sure to firmly connect the external I/O connectors and sensor connectors; otherwise, it may cause
incorrect inputs and outputs or injury.