Lx Series Installation and Operation Instructions Trinity Lx
31
Figure 5-4 Lx150-800
Figure 5-6 All Models
Concentric Vent Side Wall Clearances Roof Top Termination Clearances
Trinity Lx can also be vented through the roof. The
same clearances required for two-pipe sidewall
terminations apply to roof-top terminations. Two-
pipe roof terminations are typical for all models;
however, some termination kits are model specific.
Extra precaution must be taken to adequately support the weight of the Vent/Air-Intake
piping in applications using roof-top terminations. Failure to follow these instructions
may result in venting or appliance component failure resulting in flue gas spillage leading to property damage,
serious injury or death.
Under no circumstances may an existing chimney or chase-way be used to vent or
provide combustion intake air to a Trinity Lx. Failure to follow these instructions will
result in fire, property damage, serious injury or death.
To appliance
air-inlet
connection
From appliance
exhaust
Wall clearance
must be 1” [25
mm] from end
cap vanes to
outside of wall
Minimum
12” [305 mm]
above grade
and snow
Exhaust
Vent Outlet
(center)
Combustion
Air-Inlet
(perimeter)
Min. 12” [305 mm]
above grade and
snow level
MIN. 18” [457 mm]
above air-intake
MIN. 12”
[305 mm] above
snow level
24” [610 mm] above roof
from end cap vanes