en-938821/2 7 - 13
System Faults
7
7.14 Undeclared Speed Sensor Connected to the QVN Card
Message displayed at initialisation
ERROR: UNDECLARED SPEED SENSOR CONNECTED
TO THE QVN CARD
CONTINUE (Y/N)?
Comment
A speed sensor address is declared in parameter P71 but the sensor is not declared as connected in parameter P70
(See Parameter Manual).
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Declare the sensor as connected in parameter P70 (See Parameter Manual).
Reset the system to take the new parameter into account.
7.15 Speed Sensor Declared Several Times
Message displayed at initialisation
ERROR: SPEED SENSOR DECLARED
SEVERAL TIMES
CONTINUE (Y/N)?
Comment
A speed sensor is declared several times in parameter P71 (See Parameter Manual).
Actions
Acknowledge the message.
Y
The system is available, but the machining modes are inhibited and power cannot be applied to the system.
The "PRSOV" system fault indicator is displayed in the status window (See 3.1.3).
Enter correct sensor addresses in parameter P71 (See Parameter Manual).
Reset the system to take the new parameter into account.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NUM 1040 M and is the answer not in the manual?

NUM 1040 M Specifications

General IconGeneral
BrandNUM
Model1040 M
CategoryController
LanguageEnglish

Related product manuals