T 01460 68600
Information for Scrubber Dryer
ORIGINAL INSTRUCTIONS
READ MANUAL BEFORE USE
1. Always wear protective clothing e.g. face visor, gloves and overalls when working with batteries.
2. Whenever possible always use a properly designated and well-ventilated area for charging.
Do not smoke or bring naked ames into the charging area.
3. Remove any metallic items from hands, wrists and neck i.e. rings, chains etc. before working on a battery.
4. Never rest tools or metallic objects on top of the battery.
5. When charging is complete disconnect from the mains supply.
6. The machine must be disconnected from the supply when removing the battery.
7. To remove the batteries:- Disconnect machine from the mains supply (if charging), raise waste water tank and ensure
batteries are isolated by removing fuses. Disconnect hoses from separator and tanks, undo battery terminals and remove
batteries.
8. Only use genuine Numatic replacement batteries.
9. Do not allow the batteries to become fully discharged, it may not be possible to recharge them.
10. Do not allow one battery to be discharged separately to the other.
11. Do not mix batteries from di󰀨erent machines.
12. The batteries tted to this product are Valve Regulated Lead Acid (VRLA) gel electrolyte type.
The tting of any other type of battery may cause a safety hazard.
13. The batteries must be removed from the machine before it is scrapped.
14. Dispose of the batteries safely in accordance with local government regulations.
Battery Care
1. Battery Storage:
a. Batteries must be stored in a dry, level and clean location not exceeding a temperature range of 5°C to 25°C.
b. Batteries must by fully charged after 6 months when on-the-shelf and as a minimum every 3 months thereafter or if the
battery voltage reduces to 12.6V.
c. Batteries must be put into use within 12 months of the date of manufacture, failure to do so will lead to reduced capacity in
the eld.
(battery date code) - silver label on the battery - (e.g. 1649) = Year - 2016 / Week - 49.
d. If a battery reaches 10.5V, irreversible damage has occurred. Under this condition, a battery should not enter into service
and should be disposed of according to local authority guidelines.
2. During Use:
a. Batteries must be recharged after every use regardless of machine run time
b. If the machine is to be left dormant for any length of time complete the following:
i. Fully charge the batteries and remove the battery fuses
ii. Every 3 months insert the fuses and recharge
iii. Do not leave batteries dormant for more than 6 months
3. Warranty:
a. Batteries are warranted for 600 cycles (2 Years) providing all battery care rules are followed
b. To claim warranty the following details must be supplied
i. Serial number of the machine
ii. Battery date code (Show picture of battery date code)
iii. Date purchased
iv. Proof of Purchase
v. Maintenance history and charging regime
Precautions when working with batteries

Other manuals for Numatic CRG 8055/100T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Numatic CRG 8055/100T and is the answer not in the manual?

Numatic CRG 8055/100T Specifications

General IconGeneral
BrandNumatic
ModelCRG 8055/100T
CategoryDryer
LanguageEnglish

Related product manuals