39
ENGLISH
7.5
PROGRAMMING STAN-
DARD DOSES
It is possible to enter pre-set values for the
4 group doses and water (steam).
To do this, it is necessary to press the key
and hold it down for at least 10
seconds until the flashing keys switch off.
The doses are:
NOTE: A time setting of 0 seconds for steam
and water means this function will work
continually.
1CN 2CN 1CL 2CL
40 cc 60 cc 50 cc 85 cc
WATER
9 sec.
7.6
COPYING DOSE SET-
TINGS
It is possible to copy the dose settings for
group 1 to groups 2 or 3.
To do this, hold down the continuous key
of the group 2 or 3 for at least 8
seconds until the keys stop flashing.
If you hold down the key of the
second group, after first entering the program-
ming mode for the first group, this will access
the machine parameters setting mode; this is
signalled by the continuous key for
the second group, which will switch on.
.
1. Enabling the pump if the level is enabled.
2. Enabling the software block to enter the
dose programming function.
3. Adjusting keypad brightness.
4. Enabling the hot water pump (on machi-
nes fitted with economiser).
5. Disenabling the cup warmer
6. Restoring default settings.
1. Enabling the pump during levelling.
Use the espresso key to set pump
enabling during levelling:
if the key is lit, the pump is enabled
together with the level; if it is switched off, the
pump is not enabled with the level function.
2. Enabling the software block to enter the
dose programming function.
Use the long coffee key to enable a
software block to programme doses (key lit) or
to de-activate the block (key off).
3. Adjusting keypad brightness..
The 2 long coffees key of the second
group is used to choose the key brightness set-
ting from 5 pre-set levels.
Use the key, which will flash, to
change the level, lowering it to minimum or
returning it to maximum.
4. Enabling the hot water pump (machines
fitted with economiser only).
Use the hot water key to set the pump
to switch on while hot water is being delivered.
If the key is lit, the pump will switch on
while hot water is being delivered; if it is swit-
ched off, the pump will not switch on.
5. Disenabling the cup warmer..
Use the key to enable or disenable
cup warmer operation. If the key is lit, the cup
warmer will operate normally as set during pro-
gramming; if the key is switched off, the cup
warmer is disenabled.
7.7
PROGRAMMING OPE-
RATING PARAMETERS
The adjustments listed here below must
ONLY be performed by a Specialist
Technical Engineer
CAUTION

Related product manuals