59
ENGLISH
Sampling:
• After entering in the program of the first
group, put a jag with milk under the steam
wand and press the key, the deli-
very of steam will start.
• By pressing again the key, or if it is
reached the maximum temperature, the control
board memorizes the temperature reached.
Manually:
• After entering in the program of the first
group, press the keys of the first
group, keys of the first and second group
show the temperature starting from a mini-
mum value of 50°C.
• At every key has an value:
• Sum together the value associated to the
relevant lit key to a minimum value of 50°C
to obtain the temperature setting.
• If the key is lit, it is necessary to add the
reference value, while it is not required if the
key is not lit.
• By pressing again the key the value
is planned and the machine came back to
the general programming.
This way of setting doesn't use the delivery
of steam.
• To escape from the program and save the
setting, press the continuos key of
the first group.
Technician:
• In this steam temperature setting is possible
to plan the offset value, from -15°C to
+15°C, to obtain the correct temperature
value.
• By pressing the key of the first group,
is showed the offset value setted:
the way to show is the same of the way to
show the final steam temperature.
• The keys of the first group show a value
from 0 to 15°C,the key of the
second group show the offset sign:
• it is switched on the value is POSITIVE, if
the key is switched off is NEGATIVE.
• By releasing the key of the first group,
you memorize the value and came back to
the steam temperature setting.
Keys
1° GROUP
2° GROUP
1 °C
2 °C
10 °C
20 °C
4 °C -
8 °C -
Keys
1° GROUP
2° GROUP
1 °C
2 °C
+ o - °C
-
4 °C -
8 °C -
STANDARD DOSE PROGRAMMING
• Setting predetermined values for the four
doses of the first delivery unit is not possi-
ble. To do so, you must:
• Press the first unit continuous delivery
key and keep pressing it for at least 8
seconds, until the flashing delivery keys of
the first unit turn off.
• The standard doses are illustrated in the fol-
lowing table:
NOTE: A time of 0 seconds for water and
steam give way to their continuous
functioning.
DOSE COPYING
This procedure must be carried out for each unit
individually once after have done the setting of
the first group:
• press the continuous delivery key of
the unit you desire to copy the doses onto
and keep pressing it for at least 8 seconds,
until the flashing delivery keys turn off.
40 cc
60 cc 50 cc 85 cc 9 sec.
0 sec.