4.4.2. Switching On
Switch on the cabinet.
NUVE” logo will be on the screen for 5 seconds and display will go to stand-by position.
1.PROG: PLASTICS
1.STEP:
055.6 ºC
STAND-BY POSITION
78 %RH
DUE: 001:05
SET REC PT100 HELP
4.4.3. Programming
Push “BACK” and “NEXT” keys to select the program number.
Push “F1” key to “SET” the program.
1.PROG:
PLASTICS
CYCLE REPEAT ?
00
EXIT PID
The name of the program’s name and repetition of cycle number can be selected by using
TAB” key and selected parameter’s value can be changed by using “INCREASE
DECREASE” keys. After setting the parameters;
- Save changes to memory by pressing “ENTER” key
- or Pass to the next window without saving the changes by pressing “NEXT” key.
- or Pass to the previous window without saving the changes by pressing “BACK” key.
The next window asks you if the program will keep running or stop incase of power failure. If
you choose YES” it stops the operation, if you choose “NO” it continues the program incase
of power failure.
IS PROGRAM
AFFECTED BY
POWER FAILURE?
NO
EXIT PID
Select by using “TAB” key and selected parameter can be changed by using INCREASE
DECREASE” keys between “YES” or “NO”. After setting the parameters;