Thermal Sensors
The adapter card incorporates the ConnectX IC which operates in the range of temperatures between
0C and 105C.
There are three thermal threshold definitions which impact the overall system operation state:
•
Warning – 105°C: On managed systems only: When the device crosses the 100°C threshold, a
Warning Threshold message will be issued by the management SW, indicating to system
administration that the card has crossed the Warning threshold. Note that this temperature
threshold does not require nor lead to any action by hardware (such as adapter card shutdown).
•
Critical – 120°C: When the device crosses this temperature, the firmware will automatically shut
down the device.
•
Emergency – 130°C: In case the firmware fails to shut down the device upon crossing the
Critical threshold, the device will auto-shutdown upon crossing the Emergency (130°C)
threshold.
The card's thermal sensors can be read through the system’s SMBus. The user can read these
thermal sensors and adapt the system airflow in accordance with the readouts and the needs of the
above-mentioned IC thermal requirements.