1.
USB2000+ Fiber Optic Spectrometer
Installation and Operation Manual
Document Number 270-00000-000-02-0108
Offices: Ocean Optics, Inc. World Headquarters
830 Douglas Ave., Dunedin, FL, USA 34698
Phone 727.733.2447
Fax 727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
E-mail: Info@OceanOptics.com (General sales inquiries)
Orders@OceanOptics.com (Questions about orders)
TechSupport@OceanOptics.com (Technical support)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ocean Optics USB2000 Plus and is the answer not in the manual?

Ocean Optics USB2000 Plus Specifications

General IconGeneral
Spectral Range200-1100 nm
Pixels2048
InterfaceUSB 2.0
Power SupplyUSB powered
A/D Resolution16-bit
Detector Elements2048
Stray Light< 0.05% at 600 nm
Detector TypeLinear CCD array
Pixel size14 μm x 200 μm
Resolution0.1 nm
Dynamic Range (system)2 x 10^8
Signal-to-Noise Ratio300:1
Detector2048-element Toshiba TCD1304AP
Dimensions89.1 mm x 63.3 mm x 34.4 mm

Summary

Chapter 1: Introduction

Chapter 2: Installing the USB2000+

USB2000+ Installation

Details the physical connection and driver installation for the spectrometer.

USB2000+ Configuration

Explains how to configure the spectrometer for software use.

Chapter 3: Troubleshooting

USB2000+ Connected to Computer Prior to SpectraSuite Installation

Troubleshooting steps for issues arising from pre-installation connection.

Remove the Unknown Device from Windows Device Manager

Procedure to remove unrecognized devices from Windows Device Manager.

Remove Improperly Installed Files

Steps to clean up incorrect installation files on Windows.

Appendix A: Calibrating the Wavelength of the USB2000+

Calibrating the Spectrometer

Steps for performing the physical wavelength calibration procedure.

Calibrating the Wavelength of the Spectrometer

Detailed procedure for calibrating the spectrometer's wavelength.

Saving the New Calibration Coefficients: USB Mode

Instructions for saving updated wavelength calibration to the device.

Appendix C: Specifications

USB2000+ Specifications

Lists key performance metrics and operational parameters of the unit.

20-Pin Accessory Connector Pinout

Diagram showing the pin configuration of the 20-pin accessory connector.

20-Pin Accessory Connector – Pin Definitions and Descriptions

Defines the function of each pin on the 20-pin accessory connector.