EasyManua.ls Logo

Ocean Optics USB2000 User Manual

Ocean Optics USB2000
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
USB2000
Fiber Optic Spectrometer
Installation and Operation Manual
Document Number 170-00000-000-02-1005
Offices:
Ocean Optics, Inc.
830 Douglas Ave., Dunedin, FL., USA 34698
Phone 727.733.2447
Fax 727.733.3962
8 a.m.– 8 p.m. (Mon-Thu), 8 a.m.– 6 p.m. (Fri) EST
Ocean Optics B.V. (Europe)
Geograaf 24, 6921 EW DUIVEN, The Netherlands
Phone 31-(0)26-3190500
F
ax 31-(0)26-3190505
E-mail: Info@OceanOptics.com (General sales inquiries)
Info@OceanOpticsBV.com (European sales inquiries)
Orders@OceanOptics.com (Questions about orders)
TechSupport@OceanOptics.com (Technical support)

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Ocean Optics USB2000 and is the answer not in the manual?

Ocean Optics USB2000 Specifications

General IconGeneral
A/D Resolution16-bit
Wavelength Range200-1100 nm
Spectral Resolution0.3-10.0 nm FWHM
Detector TypeLinear CCD array
DetectorSony ILX511
InterfaceUSB
Dynamic Range1300:1 (single acquisition)
PowerUSB bus powered (2.5W max)
Integration Time65 seconds
Dimensions89.1 mm x 63.3 mm x 34.4 mm

Summary

USB2000 Introduction

Product Overview and System Requirements

Describes the spectrometer's connection, power source, and necessary hardware/software.

Interface and Shipment Details

Explains connection options, shipment contents, packing list, and calibration data sheet.

Software and Documentation Resources

Details the included CD, other documentation, and modification/repair policy.

USB2000 Specifications

How the USB2000 Works

Illustrates the light path through the USB2000 spectrometer's optical bench.

Component and Detector Specifications

Explains spectrometer components and lists CCD detector specifications.

Spectrometer Performance Specifications

Details the USB2000 spectrometer's dimensions, power, range, and optical specifications.

System Compatibility and Connectors

Outlines PC compatibility requirements and the 10-pin accessory connector location.

Installing the USB2000

USB and Serial Connection Modes

Step-by-step instructions for connecting the USB2000 via USB or serial port.

OOIBase32 Configuration

Instructions on configuring OOIBase32 to recognize and operate the USB2000.

Troubleshooting

Installation Issues and Device Manager

Addresses installation problems and steps to remove unknown devices from Device Manager.

Driver File Removal

Specific instructions for removing driver files in Windows 98.

Serial Port and Software Troubleshooting

Steps to troubleshoot serial port connections and guidance for OOIBase32 version issues.

Sample Experiments

Preparing for Experiments

Steps to configure the USB2000 and OOIBase32 before conducting experiments.

Absorbance, Transmission, and Reflection

Explains and details procedures for absorbance, transmission, and reflection measurements.

Relative Irradiance and Time Acquisition

Covers relative irradiance and time acquisition experiments and their setup.

Appendix A: Calibrating the Wavelength

Wavelength Calibration Overview and Preparation

Explains calibration basics, pixel-wavelength relationship, and required materials.

Spectrometer Calibration Procedure

Step-by-step guide for performing spectrometer wavelength calibration using spectral lines.

Saving Calibration Coefficients

Instructions for saving new calibration coefficients via USB or serial mode.

Appendix B: USB2000-FLG Spectrometer

About the USB2000-FLG

Information about the USB2000-FLG spectrometer and its enhanced sensitivity.

Using the USB2000-FLG

Instructions for installing and configuring the USB2000-FLG for Variable Delay Mode.