TO SET - ELAPSED DIVE TIME ALARM
(while in the Surface Mode)
Factory set for 3:00 (hr:min), the Alarm can be set to values
between 0:10 and 3:00 (hr:min) in increments of 5 minutes.
Press Both buttons simultaneously, release when SET: 1
appears (2 seconds).
Press and release the Left (Advance) button,
FO2
appears
with the set point value flashing.
Press the Left (Advance) button
2 more times.
The graphic
EdT
, and Alarm and Dive Time icons appear
with the
Elapsed Dive Time
value flashing (Fig. 22).
Press and release the Right (Select) button until the desired
Alarm value appears; or press and hold to scroll through
the set points.
Press the Left (Advance) button to accept the setting and
advance to PC Interface, or press and hold Both buttons
for 2 seconds to revert to Surface Mode.
Fig. 22 - Set Elapsed Dive
Time Alarm