EasyManua.ls Logo

Oceanic VEO 2.0 - User Manual

Oceanic VEO 2.0
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Oceanic VEO 2.0 and is the answer not in the manual?

Summary

FEATURES AND FUNCTIONS

DISPLAY LAYOUT

Explains the visual layout and icons on the dive computer display.

OVERVIEW

Provides a general description of the VEO 2.0 dive computer features.

MENU SYSTEM

Details the structure and navigation of the dive computer's menus.

SMARTGLO BACKLIGHT

Explains how to activate and use the automatic backlight feature.

AUDIBLE ALARM

Describes the audible alarms and the situations that trigger them.

PC INTERFACE

Details connecting the VEO to a PC for data transfer and settings.

POWER SUPPLY

Explains the battery type, life, and low battery indicators.

OPERATING MODES

NORM SURFACE MENU;MODES

Covers the interface and options for NORM mode on the surface.

ACTIVATION

Describes how to turn on and initialize the dive computer.

NORM SURF MAIN

Details the information displayed on the main screen in NORM Surface mode.

NORM SURF ALT 1

Shows dive data from the last dive in NORM mode.

NORM SURF ALT 2

Displays temperature and altitude information in NORM Surface mode.

NORM SURF ALT 3

Shows O2 percentage and PO2 alarm values in NORM mode.

FLY;SAT TIME

Explains the countdown timers for flying and desaturation.

PLAN MODE (NORM)

Plan Lead-in

Introduces the planning sequence for No Deco Dive Times.

PDPS (Pre Dive Planning Sequence)

Details the pre-dive planning steps and displayed information.

LOG MODE (NORM;GAUG)

Log Lead-in

Introduces the dive log function for NORM/GAUG modes.

Log Preview

Shows a summary of recorded dives before detailed data.

Log Data 1

Displays pre-dive surface interval and ascent time for a dive.

Log Data 2

Shows temperature and altitude data for a dive.

Log Data 3

Displays O2 percentage and PO2 values recorded during a dive.

SET F MENU (NORM FO2)

FO2 set to Air

Configures the dive computer to use Air as the gas mix.

FO2 set for Nitrox

Configures the dive computer for Nitrox dives with specific O2 percentage.

Set FO2

Allows setting the Oxygen percentage (FO2) for Nitrox dives.

Set FO2 Default

Sets the default FO2 value for automatic selection.

SET A MENU (NORM;GAUG ALARMS)

Set Audible Alarm

Configures the audible alarms for various dive conditions.

Set Depth Alarm

Sets depth-based alarms for specific dive events.

Set EDT Alarm

Configures alarms related to Elapsed Dive Time.

Set TLBG Alarm

Sets Tissue Loading Bar Graph (TLBG) related alarms.

Set DTR Alarm

Configures alarms for Dive Time Remaining (DTR).

Set PO2 Alarm

Sets alarms for Partial Pressure of Oxygen (PO2) levels.

SET U MENU (NORM;GAUG UTILITIES)

Set Wet Activation

Controls automatic activation of the dive computer upon immersion.

Set Units

Selects measurement units (Imperial/Metric).

Set Deep Stop (DS)

Enables or disables the Deep Stop feature.

Set Safety Stop (SS)

Configures the Safety Stop feature and its parameters.

Set Algorithm

Selects between DSAT or PZ+ decompression algorithms.

Set Conservative Factor (CF)

Adjusts conservatism for decompression calculations.

Set Backlight Duration (Glo)

Sets how long the backlight stays illuminated.

Set Sampling Rate (SR)

Configures the data sampling frequency for logging.

SET T MENU (TIME)

Set Date Format

Sets the display format for Month and Day.

Set Hour Format

Selects between 12-hour or 24-hour time display.

Set Time

Sets the current time on the dive computer.

Set Date

Sets the current date on the dive computer.

SET M (DIVE OP MODE)

Set Dive Operating Mode

Selects the primary operating mode (NORM, GAUG, FREE).

HISTORY MODE (NORM;GAUG)

History 1

Displays total dive time and number of dives recorded.

History 2

Shows altitude, temperature, max depth, and longest dive time.

SERIAL NUMBER

Serial Number

Displays the unit's unique serial number and firmware revision.

CLEAR (RESET)

Reset procedure

Outlines the steps to reset the dive computer to factory settings.

DIVE MODE FEATURES

BAR GRAPHS

Explains the two bar graphs: nitrogen loading (TLBG) and ascent rate (VARI).

TLBG (NORM only)

Details the Tissue Loading Bar Graph for No Deco and Deco status.

VARI (NORM and GAUG)

Describes the Variable Ascent Rate Indicator for normal and gauge modes.

ALGORITHM

Explains the choice between DSAT or PZ+ decompression algorithms.

CONSERVATIVE FACTOR (CF)

Details how the conservative factor affects NDL calculations.

DEEP STOP (DS), No Deco only

Explains the Deep Stop feature in NORM No Deco dives.

SAFETY STOP (SS), No Deco only

Configures and explains the Safety Stop feature.

DTR (DIVE TIME REMAINING)

Explains how Dive Time Remaining is calculated and displayed.

NDC (No Deco DTR)

Defines No Deco Dive Time Remaining based on nitrogen absorption.

OTR (O2 DTR)

Explains Oxygen Tolerance Remaining for Nitrox dives.

NORM DIVE MODES

NO DECO DIVE MAIN

Displays core dive information in NORM No Deco mode.

No Deco Alt 1

Shows time of day and temperature in NORM No Deco mode.

No Deco Alt 2

Displays O2, PO2, and FO2 settings for Nitrox in NORM mode.

Deep Stop (DS) Preview

Shows preview of Deep Stop depth and time before activation.

DEEP STOP MAIN

Displays details when the Deep Stop feature is active.

SAFETY STOP MAIN (On)

Displays details when the Safety Stop feature is active.

DECOMPRESSION

Explains when and how Decompression mode activates.

DECO STOP MAIN

Displays information during a decompression stop.

CV (CONDITIONAL VIOLATION)

Explains the conditional violation state and its implications.

DV 1 (DELAYED VIOLATION 1)

Details the first level of delayed violation warnings.

DV 2 (DELAYED VIOLATION 2)

Details the second level of delayed violation warnings.

DV 3 (DELAYED VIOLATION 3)

Details the third level of delayed violation warnings.

VGM (VIOLATION GAUGE MODE)

Explains the Violation Gauge Mode and its function.

HIGH PO2 (NORM only)

Describes warnings and alarms for high partial pressure of oxygen.

PO2 Alarm Main

Details the PO2 alarm display and behavior.

HIGH O2 (NORM only)

Describes warnings and alarms for high oxygen saturation levels.

DIGITAL GAUGE MODE

GAUG SURF MAIN

Shows surface interval and time in Gauge mode.

GAUG SURF ALT 1

Displays last dive's data in Gauge mode.

GAUG SURF ALT 2

Shows temperature and altitude in Gauge mode.

GAUG DIVE MAIN

Displays dive depth, max depth, and dive time in Gauge mode.

FREE DIVE MODE

FREE SURF MAIN

Shows surface interval and time for Free Dive mode.

FREE SURF ALT 1

Displays last dive's data in Free Dive mode.

FREE SURF ALT 2

Shows temperature and altitude in Free Dive mode.

CDT (Countdown Timer)

Explains the Countdown Timer feature for Free Diving.

SET FA (FREE ALARMS) MENU

Accesses settings for Free Dive specific alarms.

DA (DEPTH ALARMS)

Explains the three settable depth alarms for Free Diving.

SET M (DIVE MODE)

Sets the dive operating mode, similar to NORM.

FREE DIVE MAIN

Displays core dive information in Free Dive mode.

FREE DIVE ALARMS

Details the specific alarms for Free Dive mode.

High Nitrogen Alarms

Explains alarms related to high nitrogen loading in Free Dive.

REFERENCE

PC INTERFACE

Details connecting the VEO to a PC for data transfer and settings.

CARE AND CLEANING

Provides instructions for cleaning and maintaining the dive computer.

INSPECTIONS AND SERVICE

Outlines recommended annual inspections and service procedures.

MODULE REMOVAL FROM BOOT

Explains how to remove the dive computer module from its boot.

BATTERY REPLACEMENT

Provides step-by-step instructions for replacing the battery.

RETURNING THE MODULE TO BOOT

Instructions on how to reinsert the dive computer module into its boot.

ALTITUDE SENSING AND ADJUSTMENT

Explains how the dive computer senses and adjusts for altitude.

OCEANIC WORLD WIDE

Lists contact information for Oceanic offices globally.

TECHNICAL DATA

PZ+ ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (IMPERIAL)

Table of No Deco Limits for PZ+ algorithm at various altitudes (Imperial).

DSAT ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (METRIC)

Table of No Deco Limits for DSAT algorithm at various altitudes (Metric).

SPECIFICATIONS

Summarizes the dive computer's capabilities and performance metrics.

Summary

FEATURES AND FUNCTIONS

DISPLAY LAYOUT

Explains the visual layout and icons on the dive computer display.

OVERVIEW

Provides a general description of the VEO 2.0 dive computer features.

MENU SYSTEM

Details the structure and navigation of the dive computer's menus.

SMARTGLO BACKLIGHT

Explains how to activate and use the automatic backlight feature.

AUDIBLE ALARM

Describes the audible alarms and the situations that trigger them.

PC INTERFACE

Details connecting the VEO to a PC for data transfer and settings.

POWER SUPPLY

Explains the battery type, life, and low battery indicators.

OPERATING MODES

NORM SURFACE MENU;MODES

Covers the interface and options for NORM mode on the surface.

ACTIVATION

Describes how to turn on and initialize the dive computer.

NORM SURF MAIN

Details the information displayed on the main screen in NORM Surface mode.

NORM SURF ALT 1

Shows dive data from the last dive in NORM mode.

NORM SURF ALT 2

Displays temperature and altitude information in NORM Surface mode.

NORM SURF ALT 3

Shows O2 percentage and PO2 alarm values in NORM mode.

FLY;SAT TIME

Explains the countdown timers for flying and desaturation.

PLAN MODE (NORM)

Plan Lead-in

Introduces the planning sequence for No Deco Dive Times.

PDPS (Pre Dive Planning Sequence)

Details the pre-dive planning steps and displayed information.

LOG MODE (NORM;GAUG)

Log Lead-in

Introduces the dive log function for NORM/GAUG modes.

Log Preview

Shows a summary of recorded dives before detailed data.

Log Data 1

Displays pre-dive surface interval and ascent time for a dive.

Log Data 2

Shows temperature and altitude data for a dive.

Log Data 3

Displays O2 percentage and PO2 values recorded during a dive.

SET F MENU (NORM FO2)

FO2 set to Air

Configures the dive computer to use Air as the gas mix.

FO2 set for Nitrox

Configures the dive computer for Nitrox dives with specific O2 percentage.

Set FO2

Allows setting the Oxygen percentage (FO2) for Nitrox dives.

Set FO2 Default

Sets the default FO2 value for automatic selection.

SET A MENU (NORM;GAUG ALARMS)

Set Audible Alarm

Configures the audible alarms for various dive conditions.

Set Depth Alarm

Sets depth-based alarms for specific dive events.

Set EDT Alarm

Configures alarms related to Elapsed Dive Time.

Set TLBG Alarm

Sets Tissue Loading Bar Graph (TLBG) related alarms.

Set DTR Alarm

Configures alarms for Dive Time Remaining (DTR).

Set PO2 Alarm

Sets alarms for Partial Pressure of Oxygen (PO2) levels.

SET U MENU (NORM;GAUG UTILITIES)

Set Wet Activation

Controls automatic activation of the dive computer upon immersion.

Set Units

Selects measurement units (Imperial/Metric).

Set Deep Stop (DS)

Enables or disables the Deep Stop feature.

Set Safety Stop (SS)

Configures the Safety Stop feature and its parameters.

Set Algorithm

Selects between DSAT or PZ+ decompression algorithms.

Set Conservative Factor (CF)

Adjusts conservatism for decompression calculations.

Set Backlight Duration (Glo)

Sets how long the backlight stays illuminated.

Set Sampling Rate (SR)

Configures the data sampling frequency for logging.

SET T MENU (TIME)

Set Date Format

Sets the display format for Month and Day.

Set Hour Format

Selects between 12-hour or 24-hour time display.

Set Time

Sets the current time on the dive computer.

Set Date

Sets the current date on the dive computer.

SET M (DIVE OP MODE)

Set Dive Operating Mode

Selects the primary operating mode (NORM, GAUG, FREE).

HISTORY MODE (NORM;GAUG)

History 1

Displays total dive time and number of dives recorded.

History 2

Shows altitude, temperature, max depth, and longest dive time.

SERIAL NUMBER

Serial Number

Displays the unit's unique serial number and firmware revision.

CLEAR (RESET)

Reset procedure

Outlines the steps to reset the dive computer to factory settings.

DIVE MODE FEATURES

BAR GRAPHS

Explains the two bar graphs: nitrogen loading (TLBG) and ascent rate (VARI).

TLBG (NORM only)

Details the Tissue Loading Bar Graph for No Deco and Deco status.

VARI (NORM and GAUG)

Describes the Variable Ascent Rate Indicator for normal and gauge modes.

ALGORITHM

Explains the choice between DSAT or PZ+ decompression algorithms.

CONSERVATIVE FACTOR (CF)

Details how the conservative factor affects NDL calculations.

DEEP STOP (DS), No Deco only

Explains the Deep Stop feature in NORM No Deco dives.

SAFETY STOP (SS), No Deco only

Configures and explains the Safety Stop feature.

DTR (DIVE TIME REMAINING)

Explains how Dive Time Remaining is calculated and displayed.

NDC (No Deco DTR)

Defines No Deco Dive Time Remaining based on nitrogen absorption.

OTR (O2 DTR)

Explains Oxygen Tolerance Remaining for Nitrox dives.

NORM DIVE MODES

NO DECO DIVE MAIN

Displays core dive information in NORM No Deco mode.

No Deco Alt 1

Shows time of day and temperature in NORM No Deco mode.

No Deco Alt 2

Displays O2, PO2, and FO2 settings for Nitrox in NORM mode.

Deep Stop (DS) Preview

Shows preview of Deep Stop depth and time before activation.

DEEP STOP MAIN

Displays details when the Deep Stop feature is active.

SAFETY STOP MAIN (On)

Displays details when the Safety Stop feature is active.

DECOMPRESSION

Explains when and how Decompression mode activates.

DECO STOP MAIN

Displays information during a decompression stop.

CV (CONDITIONAL VIOLATION)

Explains the conditional violation state and its implications.

DV 1 (DELAYED VIOLATION 1)

Details the first level of delayed violation warnings.

DV 2 (DELAYED VIOLATION 2)

Details the second level of delayed violation warnings.

DV 3 (DELAYED VIOLATION 3)

Details the third level of delayed violation warnings.

VGM (VIOLATION GAUGE MODE)

Explains the Violation Gauge Mode and its function.

HIGH PO2 (NORM only)

Describes warnings and alarms for high partial pressure of oxygen.

PO2 Alarm Main

Details the PO2 alarm display and behavior.

HIGH O2 (NORM only)

Describes warnings and alarms for high oxygen saturation levels.

DIGITAL GAUGE MODE

GAUG SURF MAIN

Shows surface interval and time in Gauge mode.

GAUG SURF ALT 1

Displays last dive's data in Gauge mode.

GAUG SURF ALT 2

Shows temperature and altitude in Gauge mode.

GAUG DIVE MAIN

Displays dive depth, max depth, and dive time in Gauge mode.

FREE DIVE MODE

FREE SURF MAIN

Shows surface interval and time for Free Dive mode.

FREE SURF ALT 1

Displays last dive's data in Free Dive mode.

FREE SURF ALT 2

Shows temperature and altitude in Free Dive mode.

CDT (Countdown Timer)

Explains the Countdown Timer feature for Free Diving.

SET FA (FREE ALARMS) MENU

Accesses settings for Free Dive specific alarms.

DA (DEPTH ALARMS)

Explains the three settable depth alarms for Free Diving.

SET M (DIVE MODE)

Sets the dive operating mode, similar to NORM.

FREE DIVE MAIN

Displays core dive information in Free Dive mode.

FREE DIVE ALARMS

Details the specific alarms for Free Dive mode.

High Nitrogen Alarms

Explains alarms related to high nitrogen loading in Free Dive.

REFERENCE

PC INTERFACE

Details connecting the VEO to a PC for data transfer and settings.

CARE AND CLEANING

Provides instructions for cleaning and maintaining the dive computer.

INSPECTIONS AND SERVICE

Outlines recommended annual inspections and service procedures.

MODULE REMOVAL FROM BOOT

Explains how to remove the dive computer module from its boot.

BATTERY REPLACEMENT

Provides step-by-step instructions for replacing the battery.

RETURNING THE MODULE TO BOOT

Instructions on how to reinsert the dive computer module into its boot.

ALTITUDE SENSING AND ADJUSTMENT

Explains how the dive computer senses and adjusts for altitude.

OCEANIC WORLD WIDE

Lists contact information for Oceanic offices globally.

TECHNICAL DATA

PZ+ ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (IMPERIAL)

Table of No Deco Limits for PZ+ algorithm at various altitudes (Imperial).

DSAT ALGORITHM >> NDLS (HR:MIN) AT ALTITUDE (METRIC)

Table of No Deco Limits for DSAT algorithm at various altitudes (Metric).

SPECIFICATIONS

Summarizes the dive computer's capabilities and performance metrics.

Oceanic VEO 2.0 Specifications

General IconGeneral
BrandOceanic
ModelVEO 2.0
CategoryDiving Instrument
LanguageEnglish

Related product manuals