Code
Malfunc-
Error description Possible cause/ remedy
9 9 Er 47: De-icing malfunction
Insufficient de-icing energy
Evaporator/Sensor
Check the refrigerant circuit (OCHSNER)
129 129
Er 48: TQE sen-
sor/evaporator 1 defect
Replace sensor
130 130
Er 49: TQA sen-
sor/evaporator 2 defect
Replace sensor
12 12 Er 50: Expansion valve
Check the function of the EEV
(OCHSNER)
1 1
Er 56: Flow rate heat
source
Insufficient heat source energy, heat
source pump/filter
insufficient flow rate at heat source
2 2
Er 57: Frost protection of
heat source
Insufficient heat source energy, heat
source temperature too low,
check heat source, check heat source
pump/filter, clean water filter, ground
3 3
Er 58: Motor protection
heat source
Check motor protection, check wiring
to motor, motor protection relay,
phase defect/overload, thermo-contact
143 143
Er 59: Sensor breakage
TWV + TWR
Check sensor
144 144
Er 60: Sensor breakage
TQA + TQE
Check sensor
42 42
Er 71: Bus malfunction,
room remote unit
Check eBus wiring