77
<Connection>
3
1
2
4
3
Drawer 1
Printer
Cable
6
4
Drawer Kick
Solenoid
(24 or bigger)
2
Drawer
Open/Close
6
5
Drawer 2
5
Drawer Kick
Solenoid
(24
or bigger)
4
Caution: The drawer connection cable should be of the shielded type.
Caution: Simultaneous drive from the two drives is not available.
Caution: Specify the ON time and OFF time (t1 and t2) for the drawer
using the pulse generation command (ESC p m t1 t2).
Caution: Set the drive duty cycle for the drawer in accordance with the
following formula: ON time/(ON time + OFF time) 0.2
Caution: Always use printer power (connector pin 4) for the drawer
power.
Caution: Use a drawer kick solenoid with a resistance value of at least
24. If it is under 24, the solenoid may be damaged by
excess current.
Caution: This product uses a special-purpose modular connector for
the cash drawer and customer display connector. Do not
attempt to use other types of connectors such as public
telephone connectors.