10 Technical specifications
59
Semiconductor sensors (OLCT 100 XP)
Common characteristics
Measurement principle :
semiconductor
Temperature range :
-20°C to +55°C
Relative humidity :
20 to 95% RH (non-condensing relative humidity)
Pressure :
atmospheric ± 10%
Lifetime (typical) :
40 months
Storage conditions :
-20 to 50 °C, 20 to 60% RH, 1 bar ± 10%, 6 months
maximum
Warm-up time (max) :
4 hours to first sw itching on pow er
Type of gas
Measurement
range
Accuracy
T
50
/ T
90
(s)
Methyl chloride CH
3
Cl
Methylene chloride CH
2
Cl
2
500 ppm
500 ppm
+/- 15% (from 20 to
70% FS)
25/50
Freon R12
Freon R22
Freon R123
FX56
1 %vol
2,000 ppm
2,000 ppm
2,000 ppm
+/- 15% (from 20 to
70% FS)
25 / 50
Freon R134a
Freon R11
Freon R23
Freon R143a
Freon R404a
Freon R507
Freon R410a
Freon R32
Freon R407c
Freon 408a
2,000 ppm
1 % vol
1 % vol
2,000 ppm
2,000 ppm
2,000 ppm
1,000 ppm
1,000 ppm
1,000 ppm
4,000 ppm
+/- 15% (from 20 to
70% FS)
25 / 50
Ethanol
Toluene
Isopropanol
2-butanone ( MEK)
Xylene
R1234yf
R1234ze
500 ppm
500 ppm
500 ppm
500 ppm
500 ppm
1000ppm
1000ppm
+/- 15% (from 20 to
70% FS)
25 / 50