3
4
EN - 12
ENGLISH
6 - TROUBLESHOOTING
LED status Operating conditions What to do ?
Green Led mod-bus
(4)
OFF Not permitted Check connection with
the display and restart the
terminal
Slowlyashing Mod-bus enabled but not
connected to the terminal
Check the connection
cable with the terminal
board (A)
Quicklyashing Mod-bus enabled and
connected to the terminal
The device is connected
andreadyforconguration
Before proceeding with the check of the wireless connection, make
sure the mod-bus is enabled and connected to the terminal.
LED status Operating conditions What to do ?
Blu Led cloud
(3)
OFF Wireless connection not
enabled
Check connection with the
display and perform the
pairing procedure
Slowlyashing
(one second)
Wireless connection active
butnotcongured
Performthe conguration
procedure through the APP
Steady Wireless connection active
andcongured
The device is congured
and ready for use