This chapter describes how to replace the toner/developper cartridge and drum
cartridge and how to clean the unit.
TONER/DEVELOPER CARTRIDGE REPLACEMENT
The toner/developper cartridge replacement required ( ) indicator will light up when toner is
needed. For more information on purchasing the toner/developper cartridge, see "ABOUT
SUPPLIES AND OPTIONS" (p.72). If copying is continued while the indicator is lit, copies will
gradually become lighter until the unit stops and the indicator begins blinking. Replace the old
toner/developper cartridge by following the procedure below.
1
Open the multi-bypass tray, side cover, and front cover, in that
order.
To open the multi-bypass tray, see "The multi-bypass tray" (p.17). To open
the side cover and front cover, see "INSTALLING THE TONER/
DEVELOPER CARTRIDGE" (p.10).
2
Gently pull the toner/developper
cartridge out while pressing the lock
release button.
3
Install a new toner/developper cartridge. To install the new cartridge,
see "INSTALLING THE TONER/DEVELOPER CARTRIDGE" (p.10).
Be sure to use only genuine OLIVETTI parts and supplies.
• After the unit stops, it may be possible to make a few more copies by taking
the toner/developper cartridge out of the unit, shaking it horizontally, then
reinstalling it. If copying is not possible after this operation, replace the
toner/developper cartridge.
• During long copy run of a dark original, the toner/developper cartridge
replacement required ( ) indicator may light up, the start ( )
indicator blink, and the unit stops, even though toner is left. The unit
will feed toner up to 2 minutes and then the start ( ) indicator will
light up. Press the start ( ) key to restart copying.
Dispose of the old toner/developper cartridge in accordance with local
regulations.