INSTRUCTIONS
INDUSTRIAL VIDEOSCOPE
IPLEX RX series
IPLEX RT series
IV9620RX
IV9635RX
IV9650RX
IV9675RX
IV9420RX
IV9435RX
IV9620RT
IV9635RT
IV9650RT
IV9675RT
IV9420RT
IV9435RT

Table of Contents

Questions and Answers

  • J
    justindouglasSep 23, 2025
    How to fix poor color reproduction on my Olympus Analytical Instruments?
    • A
      amandafriedmanSep 23, 2025
      To correct poor color reproduction on your Olympus Analytical Instruments, re-adjust the white balance.
  • S
    Sheri HarrisAug 23, 2025
    What to do if I see a 'LOW BATTERY' message on my Olympus Analytical Instruments?
    • D
      Dr. Melissa McclainAug 23, 2025
      If you see a 'LOW BATTERY' message on your Olympus Analytical Instruments, immediately stop any image recording, copying, USB formatting, or deleting operations. Replace the battery or connect the AC adapter to continue using the instrument.
  • C
    Christopher CarlsonAug 25, 2025
    Why my Olympus Analytical Instruments system cannot be turned on?
    • C
      Cheryl BenjaminAug 26, 2025
      If the system cannot be turned on, ensure the AC adapter or battery is correctly connected. Also, verify that you are pressing the power button on the main unit. If it still fails to turn on, check that you are using the designated AC adapter or battery for the Olympus Analytical Instruments.
  • D
    david01Aug 26, 2025
    What to do if my Olympus Analytical Instruments shows 'RECORDING MEDIA FULL'?
    • S
      Steven AdamsAug 26, 2025
      To address a 'RECORDING MEDIA FULL' error on your Olympus Analytical Instruments, delete any unnecessary data from the USB flash drive to free up space. Alternatively, replace the current USB flash drive with a new one.
  • R
    Rhonda BradleyAug 27, 2025
    What to do if Olympus Analytical Instruments shows 'IMAGE CAPTURE ERROR'?
    • C
      Charles ParrishAug 27, 2025
      If you encounter an 'IMAGE CAPTURE ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then turn it on again.
  • K
    kclarkSep 16, 2025
    Why can't angulation be returned to its original attitude on my Olympus Analytical Instruments?
    • D
      Duane PatelSep 16, 2025
      If the angulation of your Olympus Analytical Instruments cannot be returned to its original attitude, the angulation lock might be engaged. Press down the [ANGLE LOCK] lever to release the angulation lock.
  • R
    Robert AdkinsSep 13, 2025
    Why is the illumination dim on my Olympus Analytical Instruments?
    • J
      Jennifer ValdezSep 13, 2025
      If the illumination is dim on your Olympus Analytical Instruments, wipe the optical adapter tip with a clean piece of gauze or a cotton swab.
  • C
    Chris CooperSep 14, 2025
    What to do if my Olympus Analytical Instruments system cannot be turned off?
    • E
      Emily MartinSep 14, 2025
      If the system cannot be turned off, remove the AC adapter or the battery from the main unit to turn off the power.
  • L
    Lindsay CarlsonSep 5, 2025
    Why is the illumination not working on my Olympus Analytical Instruments?
    • R
      Renee StephensSep 5, 2025
      If the illumination on your Olympus Analytical Instruments does not light up, first ensure the LIGHT button is turned on. If it still doesn't work, check if the insertion tube's distal end or the optical adapter is dirty and wipe it with a clean piece of gauze or cotton swab. You can also use a brush to remove any foreign matter.
  • B
    Benjamin FletcherSep 3, 2025
    What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (DISTAL END)'?
    • A
      Amy BlackSep 3, 2025
      If you get a 'HIGH TEMPERATURE (DISTAL END)' message on your Olympus Analytical Instruments, immediately pull the insertion tube out of the observation object.

Summary

Important Information - Please Read Before Use

Safety Precautions

General Safety Precautions

Lists critical safety guidelines for handling the instrument, covering usage environments and operational warnings.

Battery Precautions

Pre-observation;Pre-operation Preparation and Inspection

Pre-observation Preparation

Guides users through initial steps, including preparing the power supply (battery or AC adapter).

Pre-operation Preparation

Covers essential pre-use procedures like attaching the optical adapter, powering on, and checking the battery level.

Pre-operation;Post-operation Inspections

Outlines a checklist for inspecting the instrument before and after use to identify any abnormalities.

Basic Operation

Viewing an Observation Object

Explains how to turn on illumination, insert the tube, and control angulation for observation.

Adjusting the Image Display

Covers functions for freezing images, zooming, and adjusting image brightness and display modes.

Adjusting Image Brightness

Details how to switch GAIN modes and adjust image brightness using the BRT lever.

Recording Images

Explains the process of preparing the USB flash drive and specifying recording settings for still and movie images.

Replaying an Image

Guides on how to display recorded images in full-screen or thumbnail views and navigate through them.

Displaying a PDF File (RX only)

Provides steps for preparing and displaying PDF files on the instrument's screen.

Menu Operations and Functions

Performing Menu Operations

Details how to navigate and select options within the instrument's menu system using the joystick.

Stereo Measurement Procedures (RX (stereo measurement function) only)

Measurement Flow

Illustrates the sequence of steps for performing stereo measurements, from adapter attachment to value checking.

Checking Measurement Values

Details the procedure for confirming measurement accuracy before and after operations.

Storage and Maintenance

Troubleshooting

Troubleshooting Guide

Offers guidance on resolving common issues and interpreting error messages displayed by the instrument.

Specifications

Operating Environment

Specifies the recommended operating temperatures, humidity, and liquid resistance for the instrument.

Olympus IPLEX IV9420RT Specifications

General IconGeneral
BrandOlympus
ModelIPLEX IV9420RT
CategoryAnalytical Instruments
LanguageEnglish