How to fix poor color reproduction on my Olympus Analytical Instruments?
- MMaureen MorrisSep 23, 2025
To correct poor color reproduction on your Olympus Analytical Instruments, re-adjust the white balance.

How to fix poor color reproduction on my Olympus Analytical Instruments?
To correct poor color reproduction on your Olympus Analytical Instruments, re-adjust the white balance.
What to do if I see a 'LOW BATTERY' message on my Olympus Analytical Instruments?
If you see a 'LOW BATTERY' message on your Olympus Analytical Instruments, immediately stop any image recording, copying, USB formatting, or deleting operations. Replace the battery or connect the AC adapter to continue using the instrument.
Why my Olympus Analytical Instruments system cannot be turned on?
If the system cannot be turned on, ensure the AC adapter or battery is correctly connected. Also, verify that you are pressing the power button on the main unit. If it still fails to turn on, check that you are using the designated AC adapter or battery for the Olympus Analytical Instruments.
What to do if my Olympus Analytical Instruments shows 'RECORDING MEDIA FULL'?
To address a 'RECORDING MEDIA FULL' error on your Olympus Analytical Instruments, delete any unnecessary data from the USB flash drive to free up space. Alternatively, replace the current USB flash drive with a new one.
What to do if Olympus Analytical Instruments shows 'IMAGE CAPTURE ERROR'?
If you encounter an 'IMAGE CAPTURE ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then turn it on again.
Why can't angulation be returned to its original attitude on my Olympus Analytical Instruments?
If the angulation of your Olympus Analytical Instruments cannot be returned to its original attitude, the angulation lock might be engaged. Press down the [ANGLE LOCK] lever to release the angulation lock.
Why is the illumination dim on my Olympus Analytical Instruments?
If the illumination is dim on your Olympus Analytical Instruments, wipe the optical adapter tip with a clean piece of gauze or a cotton swab.
What to do if my Olympus Analytical Instruments system cannot be turned off?
If the system cannot be turned off, remove the AC adapter or the battery from the main unit to turn off the power.
Why is the illumination not working on my Olympus Analytical Instruments?
If the illumination on your Olympus Analytical Instruments does not light up, first ensure the LIGHT button is turned on. If it still doesn't work, check if the insertion tube's distal end or the optical adapter is dirty and wipe it with a clean piece of gauze or cotton swab. You can also use a brush to remove any foreign matter.
What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (DISTAL END)'?
If you get a 'HIGH TEMPERATURE (DISTAL END)' message on your Olympus Analytical Instruments, immediately pull the insertion tube out of the observation object.
| Brand | Olympus |
|---|---|
| Model | IPLEX IV9675RT |
| Category | Analytical Instruments |
| Language | English |
Explains signal words used throughout the manual for hazards and notes.
Lists general guidelines for safe handling and operation of the instrument.
Details critical safety guidelines for handling and charging batteries.
Covers steps for preparing the power supply before instrument use.
Details essential procedures to perform before operating the instrument.
Lists items to inspect before and after using the instrument.
Guides on inserting the insertion tube and operating angulation for observation.
Covers functions like freezing, zooming, and adjusting image brightness.
Details the procedures for capturing still and movie images.
Guides on viewing recorded images in full-screen or thumbnail views.
Outlines the step-by-step sequence for performing stereo measurements.
Details the correct procedure for mounting the stereo optical adapter.
Explains how to add or update stereo optical adapter information in the main unit.
Verifies the accuracy of measurement values before and after operations.
Covers selecting measurement methods and specifying measurement points.
Provides solutions for common error messages and operational problems.