INSTRUCTIONS
INDUSTRIAL VIDEOSCOPE
IPLEX RX series
IPLEX RT series
IV9620RX
IV9635RX
IV9650RX
IV9675RX
IV9420RX
IV9435RX
IV9620RT
IV9635RT
IV9650RT
IV9675RT
IV9420RT
IV9435RT

Table of Contents

Questions and Answers

  • V
    Victor BowenSep 23, 2025
    How to fix poor color reproduction on my Olympus Analytical Instruments?
    • D
      David RodgersSep 23, 2025
      To correct poor color reproduction on your Olympus Analytical Instruments, re-adjust the white balance.
  • D
    Dominique PorterAug 23, 2025
    What to do if I see a 'LOW BATTERY' message on my Olympus Analytical Instruments?
    • A
      Anne ReedAug 23, 2025
      If you see a 'LOW BATTERY' message on your Olympus Analytical Instruments, immediately stop any image recording, copying, USB formatting, or deleting operations. Replace the battery or connect the AC adapter to continue using the instrument.
  • S
    scottramirezAug 25, 2025
    Why my Olympus Analytical Instruments system cannot be turned on?
    • M
      Michael KelleyAug 25, 2025
      If the system cannot be turned on, ensure the AC adapter or battery is correctly connected. Also, verify that you are pressing the power button on the main unit. If it still fails to turn on, check that you are using the designated AC adapter or battery for the Olympus Analytical Instruments.
  • C
    Christine PittmanAug 27, 2025
    What to do if my Olympus Analytical Instruments shows 'RECORDING MEDIA FULL'?
    • J
      Justin BlakeAug 27, 2025
      To address a 'RECORDING MEDIA FULL' error on your Olympus Analytical Instruments, delete any unnecessary data from the USB flash drive to free up space. Alternatively, replace the current USB flash drive with a new one.
  • T
    Thomas LeeAug 27, 2025
    What to do if Olympus Analytical Instruments shows 'IMAGE CAPTURE ERROR'?
    • C
      Cynthia MartinAug 27, 2025
      If you encounter an 'IMAGE CAPTURE ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then turn it on again.
  • V
    Valerie SmithSep 16, 2025
    Why can't angulation be returned to its original attitude on my Olympus Analytical Instruments?
    • B
      Brenda LopezSep 16, 2025
      If the angulation of your Olympus Analytical Instruments cannot be returned to its original attitude, the angulation lock might be engaged. Press down the [ANGLE LOCK] lever to release the angulation lock.
  • K
    Kevin MasonSep 13, 2025
    Why is the illumination dim on my Olympus Analytical Instruments?
    • A
      Amber SmithSep 13, 2025
      If the illumination is dim on your Olympus Analytical Instruments, wipe the optical adapter tip with a clean piece of gauze or a cotton swab.
  • P
    Phillip WoodSep 14, 2025
    What to do if my Olympus Analytical Instruments system cannot be turned off?
    • E
      Elizabeth HoganSep 15, 2025
      If the system cannot be turned off, remove the AC adapter or the battery from the main unit to turn off the power.
  • V
    Vanessa CookSep 5, 2025
    Why is the illumination not working on my Olympus Analytical Instruments?
    • L
      Lisa GlennSep 5, 2025
      If the illumination on your Olympus Analytical Instruments does not light up, first ensure the LIGHT button is turned on. If it still doesn't work, check if the insertion tube's distal end or the optical adapter is dirty and wipe it with a clean piece of gauze or cotton swab. You can also use a brush to remove any foreign matter.
  • C
    Cassandra DavidsonSep 3, 2025
    What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (DISTAL END)'?
    • J
      jason67Sep 3, 2025
      If you get a 'HIGH TEMPERATURE (DISTAL END)' message on your Olympus Analytical Instruments, immediately pull the insertion tube out of the observation object.

Summary

Introduction

Important Information-Please Read Before Use

Crucial warnings and notes to be read before operating the instrument.

Safety Precautions

Outlines critical safety measures for handling the instrument, including DANGER, WARNING, and CAUTION.

Pre-observation;Pre-operation Preparation and Inspection

Pre-operation Preparation

Procedures to follow before starting an operation, such as attaching adapters and turning on power.

Pre-operation;Post-operation Inspections

Checklist for inspections before and after instrument use to ensure proper function.

Basic Operation

Viewing an Observation Object

Guides the user on how to view an object using the instrument, including angulation and locking.

Adjusting the Image Display

Covers adjusting image settings like freeze, zoom, and brightness for optimal viewing.

Adjusting Image Brightness

Explains how to adjust image brightness, gain modes, and display high-sensitivity images.

Recording Images

Instructions on how to record still and movie images onto a USB flash drive.

Recording a Still Image

Step-by-step guide for capturing still images, including folder selection and file naming.

Recording a Movie Image

Step-by-step guide for capturing movie images, including folder selection and confirmation.

Stereo Measurement Procedures (RX (stereo measurement function) only)

Measurement Flow

Overview of the steps involved in stereo measurement, from adapter attachment to checking values.

Attaching the Stereo Optical Adapter

Procedure for correctly attaching the stereo optical adapter to the insertion tube's distal end.

Registering the New Stereo Optical Adapter or Re-registering the Stereo Optical Adapter

Steps to register or re-register the stereo optical adapter to ensure accurate measurement.

Checking Measurement Values

Verifying measurement accuracy by comparing values before and after operations.

Troubleshooting

Troubleshooting Guide

Provides solutions for common error messages and problems encountered with the instrument.

Olympus IPLEX IV9620RX Specifications

General IconGeneral
CategoryIndustrial Videoscope
Field of View90°
Light SourceLED
Resolution640 x 480 pixels
ModelIV9620RX
Storage Temperature-25 °C to 60 °C