What to do if Olympus Analytical Instruments shows 'IMAGER ERROR'?
- BbgreeneSep 8, 2025
If you encounter an 'IMAGER ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then on again.

What to do if Olympus Analytical Instruments shows 'IMAGER ERROR'?
If you encounter an 'IMAGER ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then on again.
How to improve image brightness on my Olympus Analytical Instruments?
If the image brightness is not optimum on your Olympus Analytical Instruments, configure the proper setting by performing the [BRT] lever operation. Check if the objective lens on the insertion tube's distal end or the optical adapter is dirty and clean it. Also, ensure that the external monitor is correctly adjusted and the optical adapter is properly attached. If the optical adapter is old, consider replacing it.
What to do if I get an 'OVER CURRENT (USB)' error on my Olympus Analytical Instruments?
To resolve the 'OVER CURRENT (USB)' error on your Olympus Analytical Instruments, first, power off the instrument and then turn it back on. Ensure you are using a recommended USB flash drive. If the issue persists, disconnect all USB devices except the flash drive, as other connected devices might be causing the overcurrent.
What to do if my Olympus Analytical Instruments says 'NO RECORDING MEDIA'?
If your Olympus Analytical Instruments displays 'NO RECORDING MEDIA', load the USB flash drive and try again. If the problem persists, turn the instrument off, then on again.
What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (DISTAL END)'?
If you get a 'HIGH TEMPERATURE (DISTAL END)' message on your Olympus Analytical Instruments, immediately pull the insertion tube out of the observation object.
What to do if I get a 'RECORDING MEDIA ERROR' on my Olympus Analytical Instruments?
To resolve a 'RECORDING MEDIA ERROR' on your Olympus Analytical Instruments, format the USB flash drive directly on the instrument.
How to fix a blurry image on my Olympus Analytical Instruments?
If the image from your Olympus Analytical Instruments is not sharp, try wiping the objective lens on the insertion tube's distal end or the optical adapter with a clean piece of gauze or a cotton swab. Ensure the optical adapter is properly attached and that the external monitor is correctly adjusted.
Why is the operation load for articulation getting heavier on my Olympus Analytical Instruments?
If you are experiencing heavy operation load for articulation with your Olympus Analytical Instruments, the angulation lock might be engaged. Press down the [ANGLE LOCK] lever to release the angulation lock.
What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (MAIN UNIT)'?
If you see a 'HIGH TEMPERATURE (MAIN UNIT)' message on your Olympus Analytical Instruments, it indicates the main unit is overheating. Stop the inspection, allow the instrument to cool down, and then turn the power back on.
What to do if Olympus Analytical Instruments shows 'IMAGE CAPTURE ERROR'?
If you encounter an 'IMAGE CAPTURE ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then turn it on again.
| Category | Industrial Videoscope |
|---|---|
| Field of View | 90° |
| Light Source | LED |
| Resolution | 640 x 480 pixels |
| Model | IV9620RX |
| Storage Temperature | -25 °C to 60 °C |
Crucial warnings and notes to be read before operating the instrument.
Outlines critical safety measures for handling the instrument, including DANGER, WARNING, and CAUTION.
Procedures to follow before starting an operation, such as attaching adapters and turning on power.
Checklist for inspections before and after instrument use to ensure proper function.
Guides the user on how to view an object using the instrument, including angulation and locking.
Covers adjusting image settings like freeze, zoom, and brightness for optimal viewing.
Explains how to adjust image brightness, gain modes, and display high-sensitivity images.
Instructions on how to record still and movie images onto a USB flash drive.
Step-by-step guide for capturing still images, including folder selection and file naming.
Step-by-step guide for capturing movie images, including folder selection and confirmation.
Overview of the steps involved in stereo measurement, from adapter attachment to checking values.
Procedure for correctly attaching the stereo optical adapter to the insertion tube's distal end.
Steps to register or re-register the stereo optical adapter to ensure accurate measurement.
Verifying measurement accuracy by comparing values before and after operations.
Provides solutions for common error messages and problems encountered with the instrument.