INSTRUCTIONS
INDUSTRIAL VIDEOSCOPE
IPLEX RX series
IPLEX RT series
IV9620RX
IV9635RX
IV9650RX
IV9675RX
IV9420RX
IV9435RX
IV9620RT
IV9635RT
IV9650RT
IV9675RT
IV9420RT
IV9435RT

Table of Contents

Questions and Answers

  • H
    heidi17Sep 8, 2025
    What to do if Olympus Analytical Instruments shows 'IMAGER ERROR'?
    • A
      Angela SotoSep 8, 2025
      If you encounter an 'IMAGER ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then on again.
  • N
    Nicholas HartSep 7, 2025
    How to improve image brightness on my Olympus Analytical Instruments?
    • V
      vduncanSep 7, 2025
      If the image brightness is not optimum on your Olympus Analytical Instruments, configure the proper setting by performing the [BRT] lever operation. Check if the objective lens on the insertion tube's distal end or the optical adapter is dirty and clean it. Also, ensure that the external monitor is correctly adjusted and the optical adapter is properly attached. If the optical adapter is old, consider replacing it.
  • M
    Marcus CooperAug 22, 2025
    What to do if I get an 'OVER CURRENT (USB)' error on my Olympus Analytical Instruments?
    • P
      Paul PattonAug 22, 2025
      To resolve the 'OVER CURRENT (USB)' error on your Olympus Analytical Instruments, first, power off the instrument and then turn it back on. Ensure you are using a recommended USB flash drive. If the issue persists, disconnect all USB devices except the flash drive, as other connected devices might be causing the overcurrent.
  • M
    martinheatherSep 4, 2025
    What to do if my Olympus Analytical Instruments says 'NO RECORDING MEDIA'?
    • C
      cesarzamoraSep 4, 2025
      If your Olympus Analytical Instruments displays 'NO RECORDING MEDIA', load the USB flash drive and try again. If the problem persists, turn the instrument off, then on again.
  • V
    Vincent WolfeSep 3, 2025
    What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (DISTAL END)'?
    • C
      Christopher HernandezSep 3, 2025
      If you get a 'HIGH TEMPERATURE (DISTAL END)' message on your Olympus Analytical Instruments, immediately pull the insertion tube out of the observation object.
  • B
    Brian StanleySep 1, 2025
    What to do if I get a 'RECORDING MEDIA ERROR' on my Olympus Analytical Instruments?
    • R
      Richard CantrellSep 1, 2025
      To resolve a 'RECORDING MEDIA ERROR' on your Olympus Analytical Instruments, format the USB flash drive directly on the instrument.
  • B
    Bianca GravesAug 31, 2025
    How to fix a blurry image on my Olympus Analytical Instruments?
    • V
      Vincent OlsonAug 31, 2025
      If the image from your Olympus Analytical Instruments is not sharp, try wiping the objective lens on the insertion tube's distal end or the optical adapter with a clean piece of gauze or a cotton swab. Ensure the optical adapter is properly attached and that the external monitor is correctly adjusted.
  • G
    Gregory YoungAug 30, 2025
    Why is the operation load for articulation getting heavier on my Olympus Analytical Instruments?
    • M
      Marcus ClarkAug 30, 2025
      If you are experiencing heavy operation load for articulation with your Olympus Analytical Instruments, the angulation lock might be engaged. Press down the [ANGLE LOCK] lever to release the angulation lock.
  • Z
    Zachary BellAug 28, 2025
    What to do if Olympus Analytical Instruments shows 'HIGH TEMPERATURE (MAIN UNIT)'?
    • A
      Alexander MclaughlinAug 28, 2025
      If you see a 'HIGH TEMPERATURE (MAIN UNIT)' message on your Olympus Analytical Instruments, it indicates the main unit is overheating. Stop the inspection, allow the instrument to cool down, and then turn the power back on.
  • K
    kellerpamelaAug 27, 2025
    What to do if Olympus Analytical Instruments shows 'IMAGE CAPTURE ERROR'?
    • P
      Patty OwensAug 27, 2025
      If you encounter an 'IMAGE CAPTURE ERROR' on your Olympus Analytical Instruments, stop the inspection and turn the instrument off, then turn it on again.

Summary

Introduction to the IPLEX Series

Important Information and Safety Marks

Highlights crucial warnings, safety symbols, and essential pre-use information.

Safety Precautions

General Safety Guidelines

Provides essential safety guidelines for instrument handling, environment, and operation.

Battery Handling and Charging Safety

Outlines critical safety measures for battery usage, charging, and disposal.

Rating Plate and Caution Plate Identification

Pre-observation and Pre-operation Preparation

Basic Operation Procedures

Viewing Observation Objects

Guides on how to view objects, angulate the insertion tube, and lock positions.

Menu Operations and Functions

Stereo Measurement Procedures (RX Only)

Measurement Flow and Adapter Attachment

Outlines the workflow for stereo measurements, including adapter attachment.

Registering and Selecting Stereo Optical Adapters

Guides on registering new or re-registering existing stereo optical adapters.

Checking and Capturing Measurement Data

Details how to check measurement values and capture relevant image areas.

Performing Various Measurement Types

Explains how to perform measurements using different methods and screens.

Storage and Maintenance

Troubleshooting and Repair

Troubleshooting Guide and Error Messages

Lists common error messages, causes, and recommended actions for resolution.

Requesting Product Repair Services

Details the process for contacting Olympus for product repair and warranty information.

Olympus IPLEX IV9620RT Specifications

General IconGeneral
ModelIPLEX IV9620RT
CategoryIndustrial Videoscope
Resolution640 x 480 pixels
Light SourceLED
Illumination IntensityAdjustable
Recording MediaSD card
Battery LifeApprox. 2 hours
IP RatingIP55
Operating Temperature-10 to 50°C
Storage Temperature-20 °C to 60 °C
Relative Humidity15% to 90% RH (no condensation)
Insertion Tube Diameter6.0 mm
Working Length2 m
Direction of ViewForward
Display8.4 inch LCD
Image SensorCMOS
Video OutputHDMI
Power SourceLithium-ion battery
Field of View90°, 120°