OMEGA AUTOMATICS 2020 v3.0.2 17
Refer to table for setting parameters.
Parameter
7’-8’ door
8’-10’
10’+
Overload
55-65
65-85
HD
Act Delay
0-2
0-2
HD
Backcheck speed
20-22
20-24
HD
Holding time
˃5
˃5
HD
Opening speed
50-55
50-55
HD
Closing speed
35-50
35-50
HD
Latch speed
1-5
1-5
HD
Hold open
0-OFF 1-ON
0-OFF 1-ON
HD
Power assist
0-OFF 1-ON
0-OFF 1-ON
/
Reactivate
0-OFF 1-ON
0-OFF 1-ON
/
Once parameters are set the door operator is ready for learning cycle.
Check the doorway for any obstacles and make sure that the door close and open smoothly.
Check if the door is fully closed and display shows door closed press the ACT touch button.
Fig 7.5.5
The display will show “door opening”.
Door closed