OMEGA AUTOMATICS 2020 v3.0.2 23
12. Terminal description
Fig 12.1
13. Parameter description
percentage of current that the door operator will reverse if obstacle
is detected
Delay between the signal from activation device and door operator
Speed in which door travels after it engages back check
Time that the door will stay open (in sec)
Speed adjustment how fast will the door perform opening cycle
Speed adjustment how fast will the door perform closing cycle
Speed adjustment how fast will the door perform latching cycle
Ratcheting mode, holds the door on momentary trigger to act 1
terminal. Release the door on momentary trigger. (1_ON, 0_OFF)
Lock relay used for operating electric locking hardware
24VDC power terminal used to power device and looking hardware
Shared input for all dry device and as 0UDC output for power devices
RLY 1 is using for following applications: in normal setup as end switch when input
is maintained to ACT2 and common, in washroom mode it is using for occupied
indicator and in safety sensor setup it is using to inhibit the swing sensor.
Secondary activation input used for fire alarm, washroom, access control
Input used in washroom, access control and safety sensor setup
Input used in washroom, access control and safety sensor setup