OMEGA AUTOMATICS 2020 v3.0.2 18
Fig 7.5.6
The learning cycle does not register obstruction. Make sure that the path of the door is clear from obstacles.
Once the learning cycle is completed and the door is in closed position the door operator is programmed.
Connect activating device and run multiple test cycle to assure proper operation.
7.6 Programming Heavy Duty (XP) operators
After you follow the abovementioned steps of installation of the push or pull arm application, turn on the operator
then control board should recognize the encoder.
Press MENU touch button then press down touch button to see “Calibrate”.
Fig 7.6.1
Then press the SEL touch button.
Screen shows “Hit ACT to begin”.
Press ACT button and manually push the door to the maximum opening position.
Door Opening
[Learning]
Calibrate